Hardware options installation 68
Power supply configuration
CAUTION:
All power supplies installed in the server must have the same output power capacity
to operate in redundant mode. Verify that all power supplies have the same part number and
label color. When the system detects mismatched power supplies, the system displays POST
messages, does not power on the new power supply, and remains in non-redundant mode.
Label color
Output
Blue
460W
Orange
750W
Green
1,200W
Installing the redundant hot-plug power supply option
WARNING:
To reduce the risk of personal injury or damage to the equipment, the installation of
power supplies should be performed only by individuals who are qualified in servicing server
equipment and trained to deal with products capable of producing hazardous energy levels.
WARNING:
To reduce the risk of personal injury from hot surfaces, observe the thermal labels on
each power supply or module.
WARNING:
To reduce the risk of injury from electric shock hazards, do not open power
supplies. Refer all maintenance, upgrades, and servicing to qualified personnel.
CAUTION:
Electrostatic discharge (ESD) can damage electronic components. Be sure that you
are properly grounded (earthed) before beginning any installation procedure.
To install the component:
1.
Identify the redundant power supply bay ("
Rear panel components
" on page
9
).
IMPORTANT:
Power supplies for the model shown are hot-pluggable. When using the redundant
power supply option, it is not necessary to power down the server before removing or installing
a power supply.