background image

MULTICORE REMOTE ADAPTER

KA-M790G

INSTRUCTIONS

For Customer Use: 

Enter below the Serial No. which is located on the 

body.

Retain this information for future reference.

Model No.             KA-M790G

Serial No.

Thank you for purchasing this product.
Before beginning to operate this unit, please read 
the instruction manual carefully in order to make 
sure that the best possible performance is 
obtained.

LEVEL

CALL

ON

INCOM

MIC

POWER

SELECT

RM

BATT.

OFF

LST1109-001A

KA-M790G.book  Page 1  Friday, May 21, 2010  10:54 PM

Summary of Contents for KA-M790G

Page 1: ...tain this information for future reference Model No KA M790G Serial No Thank you for purchasing this product Before beginning to operate this unit please read the instruction manual carefully in order to make sure that the best possible performance is obtained LEVEL CALL ON INCOM MIC POWER SELECT RM BATT OFF LST1109 001A ...

Page 2: ...d disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges Do not allow anything to rest on the power cord Do not locate this appliance where the cord will be abused by persons walking on it Follow all warnings and instructions marked on the appliance Do not overload wall outlets and extension cords as this can result in fire or electric...

Page 3: ...on point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVE...

Page 4: ...nside Refer servicing to qualified service personnel Due to design modifications data given in this instruction book are subject to possible change without prior notice The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed close to the apparatus AVERTISSEMENT POUR EVITER LES RISQUES D INCENDIE OU D ELECTROCUTION NE PAS EXP...

Page 5: ...ties may be applicable for incorrect disposal of this waste in accordance with national legislation Business users If you wish to dispose of this product please visit our web page http www jvc eu to obtain information about the take back of the product Other Countries outside the European Union If you wish to dispose of this product please do so in accordance with applicable national legislation o...

Page 6: ...VI Introduction Safety Precautions contiuned ...

Page 7: ...VII ...

Page 8: ... System 8 Attaching this Unit to the Camera 9 Remote Control Unit Connection Connecting the Remote Control Unit 11 Connection 11 Preparations 12 Synchronizing with the Camera 12 Displaying the Return Video 12 Using the Tally Function and Call Function 13 Using the Intercom 13 List of Remote Control Unit Functions 14 Others Specifications 16 Contents ...

Page 9: ...munication with the remote control unit operator Prompter Output Terminal Outputs prompter video from the remote control unit as composite signals Main Features How to use this manual 䡵 Symbols used Note Describes precautions concerning the operation of this product Memo Describes reference information such as functions and usage restrictions of this product A Indicates the reference page numbers ...

Page 10: ...Especially when shooting in the rain 䡵 Protect this unit from getting wet when shooting on a beach In addition salt and sand may adhere to the body Be sure to clean this unit after use 䡵 Protect this unit against penetration of dust when using it in a place subject to sandy dust 䡵 When transceiver or mobile phone is used near this unit noise may enter the intercom speaker or appear on the screen T...

Page 11: ...nnected Adjust phase using RM HP250AU RM HP250DE When RM P210U RM P210E is connected When Genlock signal is input into RM P210U RM P210E Adjust phase by performing H adjustment of RM P210U RM P210E Use RM LP55U to adjust the phase if RM LP55U is connected to this system When Genlock signal is input into the camera adjust the phase by performing H adjustment of the camera Adjust using the camera ev...

Page 12: ...erminal B PROMPTER OUTPUT Prompter Output Terminal BNC For connecting the video monitor Signal prompter video signal input into the AUX input terminal of the remote control unit will be output from this terminal via the RM multi pin connector as component signals C INTERCOM Intercom Input Terminal XLR 5 Pin Input terminal for intercom headset For dynamic microphones only D Camera Connector 68 pin ...

Page 13: ...election Switch For selecting the power supply for the camera including this unit I Tally Lamp Lights up when call signals or tally signals are received from the remote control unit A Page 13 J BREAKER Breaker Button The breaker switch will trip and cut off the power if the power consumed is higher than the rated capacity When power is cut off by the breaker check for any abnormality that may have...

Page 14: ... AUTO B HIGH W BAL POWER AUTO MANU B A CLOSE OPEN PRESET LOW MID DOWN UP F3 INTERCOM LEVEL REMOTE CONTROL UNIT RM HP250 GAIN SHUTTER XLR 4P AC Power Adapter IA 60a VL 2PLUS IDX AC For GY HM790CHE GY HM790E IDX Battery Endura HL9 For GY HM790CHU GY HM790U Anton Bauer Battery Dionic90 Multicore Remote Adapter KA M790G Headset DT109 Beyerdynamic Monitor Remote Control Unit RM P210U E RM HP250AU RM HP...

Page 15: ...ra The plate is only available on IDX Batteries 3 Attach this unit to the camera A Connect Connector A of the camera to that of this unit B Store the connected connector in the storage compartment of the camera and fasten using the supplied Velcro fastener Note Make sure that the connection wires and connectors are properly stored and do not protrude out C Attach the hook of this unit to the guide...

Page 16: ...e storage compartment 䡵 IDX Store in the battery folder 䡵 Anton Bauer Store in the storage compartment of this unit Note Make sure that the connection wires and connectors are properly stored and do not protrude out 5 Attach the battery Note Do not connect a battery other than those designated For details on the type of battery that can be connected refer to the INSTRUCTIONS of the camera Attachin...

Page 17: ...l of the remote control unit s AUX VIDEO INPUT terminal output from the remote control unit connect PROMPTER OUTPUT terminal of this unit to the monitor using a BNC cable Connecting the Remote Control Unit PROMPTER OUTPUT INTERCOM RM TALLY CALL FULL AUTO BARS F2 F1 F4 MENU SHUTTER MENU SHUTTER GAIN WHITE MASTER BLACK IRIS PUSH ON DOWN UP VARIABLE PUSH ON STEP PAINT R AUTO B HIGH W BAL POWER AUTO M...

Page 18: ...input the Genlock signal You can select the device to input the Genlock signal in Genlock Input of the Others menu on the camera Note Perform system phase adjustment on the device used for Genlock signal input Displaying the Return Video 䡵 Setting To check the return video of the 26 pin camera cable using this unit set Return Input in the Others menu on the camera to AAdapterB Select an appropriat...

Page 19: ...control unit make sure that you read through its instruction manual 䡵 Call signal Send signal The CALL button on this unit lights up in red when pressed Call signals are sent to the remote control unit while the button is pressed down The TALLY lamp on the remote control unit blinks while signals are being sent Stopping signal transmission Release your finger from the CALL button to stop sending s...

Page 20: ...000 3 3 1 2000 3 3 1 4000 3 N A 1 10000 3 N A V SCAN V SCAN LEVEL GAIN MODE 0dB 3 3 3dB 3 3 6dB 3 3 9dB 3 3 12dB 3 3 15dB 3 3 18dB 3 3 24dB 3dB ALC EEI 3 3 ALC 3 N A VARIABLE Function 3 Available Not available RM HP250AU RM HP250DE RM P210U RM P210E GAIN VARIABLE LEVEL WHITE MODE MANUAL 3 3 PRESET 3 3 AUTO1 3 3 AUTO2 3 3 FAW 3 3 AUTO SET WHITE 3 3 MANUAL LEVEL R B 3 3 WHITE PAINT R B 3 3 MASTER BL...

Page 21: ...log SD H Phase on the camera 4 Equivalent to DTL H FREQ on the camera Function 3 Available Not available RM HP250AU RM HP250DE RM P210U RM P210E DETAIL MODE 3 3 LEVEL 3 3 V H BAL 3 3 DTL FRQ 4 LOW 3 3 MIDDLE 3 3 HIGH 3 3 AUTO AUTO KNEE 3 3 KNEE POINT 3 3 COLOR MATRIX GAMMA MODE 3 3 LEVEL 3 3 BLACK 3 3 ASPECT RATIO DNR MODE 3 3 LEVEL SMOOTH TRANS 3 3 LOLUX ...

Page 22: ...ent video signal output 26 pin PROMPTER OUTPUT Prompter video signal output composite video BNC Operating temperature range 5 f to 40 f Humidity 80 and below Allowable storage temperature 20 f to 60 f Power supply voltage DC 12 V Power consumption Max 3 W when GY HM790CHU GY HM790CHE standard lens is used Mass Approx 500 g Accessories Rubber Sheet x1 Instructions x1 RM PROMPTER OUTPUT INTERCOM 134...

Page 23: ...17 ...

Page 24: ...2010 Victor Company of Japan Limited KA M790G MULTICORE REMOTE ADAPTER LST1109 001A ...

Reviews: