![HP j6700 Service Handbook Download Page 67](http://html.mh-extra.com/html/hp/j6700/j6700_service-handbook_165074067.webp)
Chapter 3
67
Troubleshooting
Identifying LCD-Indicated Conditions
OFF
CBE2
IO BD
PCI SERR#; OV
A PCI device asserted SERR# multiple
times.
OFF
CBE3
IO BD
Unknown PCI err
Unknown PCI error detected.
OFF
CBE6
SYS BD
AtoE rope perr
Parity error between system I/O controller
and Rope-to-PCI bridge.
OFF
CBE7
IO BD
R2PCI intrnl err
Rope-to-PCI bridge internal data error.
OFF
CBE8
SYS BD
AtoE rope perr
Command parity error between system
I/O controller and Rope-to-PCI bridge.
OFF
CBE9
IO BD
Unknown Rope err
Unknown rope error occurred.
FLT
CBF0
SYS BD
HPMC initiated
A High-Priority Machine Check entered
the firmware HPMC handler.
FLT
CBF1
SYS BD
no OS HPMC IVA
There is no HPMC vector for the
operating system. Firmware will halt the
CPU, requiring a power cycle to recover.
FLT
CBF2
SYS BD
bad OS HPMC len
The size of the operating system HPMC
handler is invalid. Firmware will halt the
CPU, requiring a power cycle to recover.
FLT
CBF3
SYS BD
bad OS HPMC addr
The operating system HPMC handler
vector is invalid. Firmware will halt the
CPU, requiring a power cycle to recover.
FLT
CBF4
SYS BD
bad OS HPMC cksm
The operating system HPMC handler
failed the checksum test. Firmware will
halt the CPU, requiring a power cycle to
recover.
FLT
CBF5
SYS BD
OS HPMC vector 0
The size of the operating system HPMC
handler is zero. Firmware will halt the
CPU, requiring a power cycle to recover.
WRN
CBFA
SYS BD
prev HPMC logged
Firmware detected unread PIM data from
a previous HPMC and will overwrite it.
FLT
CBFB
SYS BD
brnch to OS HPMC
Branching to the operating system HPMC
handler.
FLT
CBFC
SYS BD
OS HPMC br err
Branch to the operating system HPMC
handler failed. Firmware will halt the
CPU, requiring a power cycle to recover.
FLT
CBFD
SYS BD
unknown check
The firmware trap handler didn’t detect
an HPMC, LPMC, or TOC.
FLT
CBFE
SYS BD
HPMC during TOC
A High-Priority Machine Check occurred
during Transfer of Control processing.
Table 3-1. Chassis Codes for J6700 Workstations
Ostat
Code
FRU
Message
Description
Summary of Contents for j6700
Page 1: ...Service Handbook HP VISUALIZE J6700 Workstations Manufacturing Part Number n a Edition E0501 ...
Page 8: ...8 Contents ...
Page 30: ...30 Chapter1 Product Information Monitors ...
Page 76: ...76 Chapter3 Troubleshooting Using the System Board LEDs for Troubleshooting ...
Page 100: ...100 Chapter4 Field Replaceable Units FRUs FRU Removal and Replacement ...
Page 134: ...134 Chapter5 Boot Console Handler Initial System Loader ISL Environment ...
Page 150: ...150 Appendix B SCSI Connections How To Connect An SE SCSI Device ...