130
Chapter 5
Boot Console Handler
Setting the Fan Speed
Setting the Fan Speed
There are two fan speed settings available on the J6700 workstation. The
RackMount
fan
speed is used for J6700s that are installed in a rack. The
DeskSide
fan speed is used for
J6700s that are used as desk-side systems. These fan speeds are set using the Boot
Console Handler (bch). To set the fan speeds, follow the procedures discussed in this
section.
Rack-Mount Fan Speed
If you currently have a desk-side workstation that you want to convert to a rack-mount
workstation, you need to change the workstation’s fan speed. To do this, follow this
procedure:
1. Turn on the workstation and press the
Tab
key until a select display message appears.
Select the display frequency and resolution that are best for your workstation.
2. Stop the boot process by pressing any key before the ten-second limit. This gets you to
the Boot Console Handler’s (bch) Main Menu. You will only need to do this if you have
autoboot
turned on; otherwise, the system stops at the bch Main Menu. When the
Main Menu prompt appears, type:
Main Menu: Enter command > configuration
3. Enter the following command at the Configuration Menu prompt:
Configuration Menu: Enter command > FanChoice RackMount
4. Return to the Main Menu and enter this command at the prompt to continue booting:
Main Menu: Enter command > boot
Desk-Side Fan Speed
If you currently have a rack-mount workstation that you want to convert to a desk-side
workstation, you need to change the workstation’s fan speed. To do this, follow this
procedure:
1. Turn on the workstation and press the
Tab
key until a select display message appears.
Select the display frequency and resolution that are best for your workstation.
2. Stop the boot process by pressing any key before the ten-second limit. This gets you to
the Boot Console Handler’s (bch) Main Menu. You will only need to do this if you have
autoboot
turned on; otherwise, the system stops at the bch Main Menu. When the
Main Menu prompt appears, type:
Main Menu: Enter command > configuration
Summary of Contents for j6700
Page 1: ...Service Handbook HP VISUALIZE J6700 Workstations Manufacturing Part Number n a Edition E0501 ...
Page 8: ...8 Contents ...
Page 30: ...30 Chapter1 Product Information Monitors ...
Page 76: ...76 Chapter3 Troubleshooting Using the System Board LEDs for Troubleshooting ...
Page 100: ...100 Chapter4 Field Replaceable Units FRUs FRU Removal and Replacement ...
Page 134: ...134 Chapter5 Boot Console Handler Initial System Loader ISL Environment ...
Page 150: ...150 Appendix B SCSI Connections How To Connect An SE SCSI Device ...