Identifying LCD-Indicated Conditions
FLT
7845
SYS BD
mem ctlr stat wd
Printing memory controller status word to
RS-232.
FLT
7846
SYS BD
mem err overflow
Multiple memory errors detected.
FLT
7848
SYS BD
addr not mapped
Memory address outside configured
memory space.
FLT
785
s
DIMM
MBE in DIMM
s
Destructive memory test detected an
uncorrectable memory error in DIMM s.
FLT
786
s
DIMM
SBE&MBE DIMM
s
Destructive memory test detected both an
uncorrectable and a correctable memory
error in DIMM s.
FLT
787
s
DIMM
mem err DIMM
s
Destructive memory test detected a
pattern compare error in DIMM s.
FLT
788
s
DIMM
SBE in DIMM
s
Destructive memory test detected a
correctable memory error in DIMM s.
FLT
7890
DIMM
MBE overwrt SBE
Firmware replaced a correctable memory
error entry in the PDT with an
uncorrectable memory error entry at the
same address.
FLT
7891
DIMM
dup entry in PDT
The PDT already contains an entry at
that address.
FLT
7892
SYS BD
PDT write error
Error adding the entry to the PDT.
FLT
7893
SYS BD
PDT is full
The PDT is full--cannot add new entry.
FLT
7900
SYS BD
no DMT entry
Internal error--cannot find DIMM entry.
FLT
7901
SYS BD
no rank entry
Internal error--cannot find rank entry.
FLT
7902
SYS BD
bad refrsh intvl
Computed refresh interval is invalid.
FLT
7903
SYS BD
mem intrlv fail
Cannot generate memory interleave.
FLT
7904
SYS BD
mem reloc failed
Cannot interleave with relocated range
(3.75GB - 4.0GB).
FLT
7905
SYS BD
mem intrlv error
Undefined memory interleave failure.
FLT
79FF
SYS BD
mem firmware err
Internal error--never expected this to
happen.
WRN
80F3
SYS BD
err rd IODC byte
Cannot read IODC from ROM or card.
WRN
80F4
EXT IO
boot read error
Cannot load IODC entry_init for boot
device.
WRN
80F5
EXT IO
boot exec error
Error initializing boot device.
Table 3-1. Chassis Codes for J6700 Workstations
Ostat
Code
FRU
Message
Description
Summary of Contents for j6700
Page 1: ...Service Handbook HP VISUALIZE J6700 Workstations Manufacturing Part Number n a Edition E0501 ...
Page 8: ...8 Contents ...
Page 30: ...30 Chapter1 Product Information Monitors ...
Page 76: ...76 Chapter3 Troubleshooting Using the System Board LEDs for Troubleshooting ...
Page 100: ...100 Chapter4 Field Replaceable Units FRUs FRU Removal and Replacement ...
Page 134: ...134 Chapter5 Boot Console Handler Initial System Loader ISL Environment ...
Page 150: ...150 Appendix B SCSI Connections How To Connect An SE SCSI Device ...