64
Chapter 3
Troubleshooting
Identifying LCD-Indicated Conditions
WRN
CB03
SYS BD
bad OS TOC code
The operating system TOC handler is
invalid. Firmware will soft boot the
system.
WRN
CB04
SYS BD
bad OS TOC len
The size of the operating system TOC
handler is invalid. Firmware will soft boot
the system.
WRN
CB05
SYS BD
bad OS TOC chksm
The operating system TOC handler failed
the checksum test. Firmware will soft boot
the system.
WRN
CB0A
SYS BD
prev TOC logged
Firmware detected unread PIM data from
a previous TOC and will not overwrite it.
(PIM for this TOC is lost.)
INI
CB0B
SYS BD
branch to OS TOC
Branching to the operating system TOC
handler.
WRN
CB0C
SYS BD
br OS TOC failed
Branch to the operating system TOC
handler failed. Firmware will soft boot the
system.
WRN
CB10
SYS BD
LPMC initiated
A Low-Priority Machine Check entered
the firmware LPMC handler. The handler
should log the error and return to normal
operation.
WRN
CB11
SYS BD
icache LPMC err
An instruction cache parity error caused
the LPMC.
WRN
CB12
SYS BD
dcache LPMC err
A data cache parity/ECC error caused the
LPMC.
WRN
CB13
SYS BD
dcache tag error
The parity error is in the tag portion of
the data cache.
WRN
CB14
SYS BD
dcache data err
The parity error is in the data portion of
the data cache.
FLT
CB1F
SYS BD
OS LPMC failed
Firmware couldn’t branch to the operating
system LPMC handler. It will halt the
CPU, requiring a power cycle to recover.
WRN
CB71
SYS BD
HPMC occurred
A High-Priority Machine Check caused
entry to PDCE_CHECK (the firmware
trap handler).
WRN
CB72
SYS BD
LPMC occurred
A Low-Priority Machine Check caused
entry to PDCE_CHECK (the firmware
trap handler).
Table 3-1. Chassis Codes for J6700 Workstations
Ostat
Code
FRU
Message
Description
Summary of Contents for j6700
Page 1: ...Service Handbook HP VISUALIZE J6700 Workstations Manufacturing Part Number n a Edition E0501 ...
Page 8: ...8 Contents ...
Page 30: ...30 Chapter1 Product Information Monitors ...
Page 76: ...76 Chapter3 Troubleshooting Using the System Board LEDs for Troubleshooting ...
Page 100: ...100 Chapter4 Field Replaceable Units FRUs FRU Removal and Replacement ...
Page 134: ...134 Chapter5 Boot Console Handler Initial System Loader ISL Environment ...
Page 150: ...150 Appendix B SCSI Connections How To Connect An SE SCSI Device ...