3-8
Getting Started With Switch Configuration
Configuring the ProCurve Access Controller xl Module (J8162A)
Ge
ttin
g
Sta
rte
d
With
Sw
itc
h
Co
nf
ig
u
rat
io
n
Next, configure the module with the IP address of the 740wl/760wl and its
shared secret.
access-control-server ip <ip address> secret <shared secret> <shared secret>
The shared secret and IP address here are what you configured on the 740wl/
760wl above. You enter the shared secret twice to ensure you typed it correctly.
The shared secret is case sensitive. This command tells the Access Controller
xl Module where the Access Control Server (740wl) or Integrated Access
Manager (760wl) is and allows secure communication between the module
and the 740wl/760wl. The following is an example command.
access-control-server ip 13.13.13.8 secret 7734Oh 7734Oh
Wait a few moments for the module to connect to the 740wl/760wl over the
network. To confirm that the module has connected successfully, enter the
following command:
show status
When the connection is complete between the 740wl/760wl and the Access
Controller xl Module, control of the module is turned over to the 740wl/760wl.
For more information on managing the module, see the documentation that
came with the 740wl/760wl.
For more information on the console, web browser, and SNMP management
interfaces and all the features that can be configured on the Switch 5300xl
Series, please see the
Management and Configuration Guide
on the
ProCurve Web site,
. For the latest version you can also visit
the ProCurve networking products Web site
.
Uptime: 23 hrs, 12 mins
Access Controller Function
Access Control Server: 13.13.13.8
Connected: 2 secs
Active Clients: None
Summary of Contents for J4819A
Page 2: ...stingray book Page 12 Sunday November 2 2003 9 38 AM ...
Page 3: ...ProCurve Switch 5300xl Series Installation and Getting Started Guide ...
Page 20: ......
Page 46: ......
Page 74: ......
Page 105: ......
Page 106: ......
Page 107: ...stingray book Page 12 Sunday November 2 2003 9 38 AM ...