Table 82 Cable kit part numbers
Part Number
Description
Type of Cable
389647-B21
Multi-lane A cable
Internal SAS/SATA
389650-B21
Host fan cable
Internal SAS/SATA
389653-B21
Target fan cable
Internal SAS/SATA
389659-B21
Multi-lane B cable
Internal SAS/SATA
389662-B21
Multi-lane 76-cm (30-in) cable
Internal SAS/SATA
391330-B21
Multi-lane 48-cm (19-in) cable
Internal SAS/SATA
Additional cables can be ordered from an authorized HP reseller or authorized HP service provider.
If the cable that you need is not listed here, or if you need additional ordering information, see
the HP website at
http://www.hp.com
.
Installing the HP Eight-Internal Port SAS Host Bus Adapter
On HP Integrity rx6600 servers, the HP Eight-Internal Port SAS Host Bus Adapter is supported by
HP-UX and OpenVMS operating systems. It should be installed in slot 1 if one card is to be installed,
and slot 2 if slot 1 is already occupied.
The installation procedure involves the following steps:
•
Preparing the server
•
Installing the adapter hardware.
•
Connecting the Adapter to Other Devices
•
Completing the adapter installation procedure, including updating the firmware and installing
drivers.
For more information, including configuring and troubleshooting, see the HP 8 Internal Port SAS
Host Bus Adapter (SAS Controller) Users Guide on the HP website at
http://www.hp.com/go/
integrity-iocards-docs
.
Click the link for your HP-UX version. Support guides are listed alphabetically in the “User guide”
section.
Procedure 6 Preparing the Server
To prepare the server for add or replacement:
1.
Perform a normal system shutdown.
2.
Power down the server.
3.
Power down all peripheral devices attached to the server.
4.
Unplug the AC power cord from the outlet, and then unplug it from the server
5.
Disconnect all peripheral devices attached to the server.
Procedure 7 Installing the Adapter Hardware
1.
Remove or open the server access panel and locate the PCI/PCI-X bus expansion slots. (For
detailed instructions, see the documentation that was provided with the server.)
2.
Select the appropriate core I/O slot.
3.
Open the MRL.
a.
Press the indentation on the MRL to release it from the chassis wall.
b.
Lift the edge of the MRL, and rotate it upward 90 degrees until it rests against the chassis
wall and the PCI/PCI-X/PCIe card bulkhead filler is fully exposed.
4.
Remove the PCI/PCI-X/PCIe bulkhead filler. Save it to use for if you later decide to remove
the adapter and leave the slot empty.
5.
Insert the adapter into the slot, and press it firmly into place. The contacts on the adapter edge
should be fully seated in the system board connector.
264 Upgrades