“Online Replacement (OLR)”
Describes the replacement of a PCI/PCI-X/PCIe card without powering down the server. This
action requires suspending the associated driver. The existing driver for the old card must be
compatible with the new card.
CAUTION:
If you are performing OLR on HP-UX 11i version 1 (and later), the card you install
must be exactly the same as the card you replace. This is also known as like-for-like
replacement.
•
“Removing a PCI/PCI-X/PCIe Card Offline”
Describes the removal of a PCI/PCI-X/PCIe card after powering down the server.
•
“Installing a PCI/PCI-X/PCIe Card Offline”
Describes the installation of a PCI/PCI-X/PCIe card after powering down the server.
Figure 65
shows the PCI/PCI-X/PCIe slot identification and card divider locations.
NOTE:
Slots one through eight are full-length; slots nine and ten are short-length.
Figure 65 PCI/PCI-X/PCIe Slot Identification and Card Divider Locations
9
Slot 9
5
Slot 5
1
Slot 1
2
Slot 2
10
Slot 10
6
Slot 6
7
Slot 7
3
Slot 3
11
Core I/O Board Slot
12
8
4
PCI/PCI-X/PCIe Card
Dividers
Slot 8
Slot 4
Removing and Replacing a Hot-Pluggable PCI/PCI-X/PCIe Card
193