![HP Integrity MC990 X User Manual Download Page 58](http://html.mh-extra.com/html/hp/integrity-mc990-x/integrity-mc990-x_user-manual_164437058.webp)
Table 5: MC990 X server chassis and 42U rack physical specifications
Feature
Specification
Dimensions for single MC990 X server chassis
Height: 5U 8.64 inches (22 cm)
Width: 17.5 inches (44.5 cm)
Depth: 31.8 inches (80.8 cm)
Weight of single MC990 X server chassis (fully
configured)
136 lb. (62 kg)
Dimensions for a single 24-inch wide 42U rack,
including doors and side panels
Height: 78.75 in. (200 cm)
Width: 28 in. (70.1 cm)
Depth: 45.5 in. (115.6 cm)
Shipping dimensions (single rack)
Height: 88.8 in. (225.8 cm)
Width: 44 in. (111.8 cm)
Depth: 62.75 in. (159.4 cm)
Single rack shipping weight (max)
2,070 lb. (939 kg) air cooled (approximate)
Single rack system weight installed (max)
1,579 lb. (716 kg) air cooled (approximate)
*Empty rack weight is approximately 391 lb. (177
kg)
42U rack access requirements:
Front: 48 in. (121.9 cm)
Rear: 48 in. (121.9 cm)
Top: 18 in. (45.7 cm)
Integrity MC990 X system environmental specifications
lists the environmental specifications of the Integrity MC990 X system.
Table 6: Environmental specifications
Feature
Specification
Temperature tolerance (operating)
+5 °C (41 °F) to +35 °C (95 °F) (up to 1500 m / 5000 ft.)
+5 °C (41 °F) to +30 °C (86 °F) (1500 m to 3000 m /5000 ft. to
10,000 ft.)
De-rate max ambient temperature by 1.8 °F (1 °C) per 1000 ft.
(305 m) of altitude above 5000 ft. (1525 m)
Temperature tolerance (non-
operating)
-40 °C (-40 °F) to +60 °C (140 °F)
Table Continued
58
Integrity MC990 X system environmental specifications