Figure 3-6 Sample Server-to-Server Configuration with Switch (Not Recommended)
HP APA 2–4 Port
Link Aggregation
HP APA 2–4 Port
Link Aggregation
Power
Run
Attn. Fault
Remote
Power
Run Attn.
Fault
Remote
hp
ProCurve
Switch 8000
Switch
Failover group
Figure 3-7 (page 28)
shows a sample failover group (LAN_MONITOR mode) configuration. This
configuration provides high availability network access with an active link and a standby link,
and has the following characteristics:
•
Dual switches or hubs are not required. However, dual switches and hubs provide a more
reliable network environment by removing the switch or hub as a single point of failure. If
two switches or hubs are used, there must be a data path between them to allow them to be
on the same subnet.
•
You can connect failover groups to any switch or hub.
•
The link partner does not require trunking to be enabled.
HP APA configuration examples
27