MEASurement Instructions
MEASurement Instructions
2-2
HP E4418B/E4419B Programming Guide
MEASurement Instructions
The purpose of the
MEASure
group of instructions is to acquire data using
a set of high level instructions.
The
MEASure
group of commands are structured to allow you to trade off
interchangeability with fine control of the measurement process.
MEASure?
provides a complete capability where the power meter is
configured, a measurement taken, and results returned in one operation.
Often, more precise control of the measurement is required. Therefore,
MEASure?
is complemented by providing two commands,
CONFigure
and
READ?
.
CONFigure
performs the configuration portion of the
measurement and
READ?
performs the data acquisition, postprocessing,
and data output portions of the measurement. This allows you to perform
a generic configuration of the measurement through
CONFigure
and then
customize the measurement by changing particular power meter
functions. The
READ?
then completes the measurement process.
READ?
, in turn, is broken down into two additional commands,
INITiate[:IMMediate]
and
FETCh?
.
INITiate[:IMMediate]
performs the data acquisition.
FETCh?
performs the postprocessing
function and returns the data. This allows you to perform several different
FETCh?
functions on a single set of acquired data.
The HP E4418B/E4419B power meters have several command extensions
to the SCPI standard. These are the
RELative
and
DIFFerence
nodes.
The numeric suffixes of the
CONFigure
,
FETCh
,
READ
and
MEASure?
program mnemonics in the
MEASure
group of commands refers to
windows, that is
CONFigure1
and
CONFigure2
represent the upper and
lower windows respectively.
Summary of Contents for E4418B
Page 25: ...prog book chapter1 fm 1 Mon Feb 15 09 24 37 1999 1 Power Meter Remote Operation ...
Page 138: ...prog book ch2meas fm 1 Mon Feb 15 09 24 37 1999 2 MEASurement Instructions ...
Page 200: ...prog book ch3calc fm 1 Mon Feb 15 09 24 37 1999 3 CALCulate Subsystem ...
Page 228: ...prog book ch4cal fm 1 Mon Feb 15 09 24 37 1999 4 CALibration Subsystem ...
Page 242: ...prog book ch5disp fm 1 Mon Feb 15 09 24 37 1999 5 DISPlay Subsystem ...
Page 260: ...prog book ch6form fm 1 Mon Feb 15 09 24 37 1999 6 FORMat Subsystem ...
Page 264: ...prog book ch7mem fm 1 Mon Feb 15 09 24 37 1999 7 MEMory Subsystem ...
Page 294: ...prog book ch8out fm 1 Mon Feb 15 09 24 37 1999 8 OUTput Subsystem ...
Page 302: ...prog book ch9sens fm 1 Mon Feb 15 09 24 37 1999 9 SENSe Subsystem ...
Page 360: ...prog book ch10stat fm 1 Mon Feb 15 09 24 37 1999 10 STATus Subsystem ...
Page 384: ...prog book ch11syst fm 1 Mon Feb 15 09 24 37 1999 11 SYSTem Subsystem ...
Page 420: ...prog book ch12trig fm 1 Mon Feb 15 09 24 37 1999 12 TRIGger Subsystem ...
Page 434: ...prog book ch13unit fm 1 Mon Feb 15 09 24 37 1999 13 UNIT Subsystem ...
Page 442: ...prog book ch14serv fm 1 Mon Feb 15 09 24 37 1999 14 SERVice Subsystem ...
Page 452: ...prog book ch15ieee fm 1 Mon Feb 15 09 24 37 1999 15 IEEE488 2 Command Reference ...
Page 481: ...prog book progIX doc 6 Mon Feb 15 09 24 37 1999 Index 6 HP E4418B E4419B Programming Guide ...