Chapter 12
Troubleshooting
145
Front Panel Status Messages
If an error is detected during normal operation of an HP NetServer 8500 function,
the Front Panel Status Messages appear on the LCD display. The status messages
will appear on the display, even if the front panel power switch is turned Off, as
long as, the NetServer remains connected to live AC power.
Table 12-2. Front Panel Error Messages
Display Message
Description
FPC FW Testing Please wait...
No error; Status message only.
FPC x.xx Testing Please wait....
No error; Status message only.
FPC Checksum Err
Non-fatal checksum error.
See Note 1.
FPC RAM test failed
Non-fatal front panel controller error.
See Note 2.
FPC Registers test failed
Non-fatal front panel controller error.
See Note 2.
FPC FRU access test failed
Non-fatal front panel controller error.
See Note 2.
FPC LCD test failed
Non-fatal front panel controller error.
See Note 2.
PSC is not ready
Power share controller failure.
See Note 2.
PSC Checksum Err
Error detected in controller code.
See Note 1.
Self-test done FP ready
No error; Status message only.
Reading SEL Please wait
No error; Status message only.
HP NetServer LXr 8500
No error; Status message only.
ERROR: Unable to power on
Error in power share controller.
See Note 2.
System is powered off
No error: Status message only.