Rack Mounting the HP NetServer
102
The threaded inserts are located near the power inlet receptacle.
Left Rear
Rack Column
Rear of NetServer
Cable Management Arm
Figure 8-12. Attaching the Cable Management Arm
4. Attach the flange to the HP NetServer with the two 6-32 pan head Torx
®
T-15 screws, included with the Arm. See Figure 8-12.
5. Attach the other flange of the cable arm to the rear column of the rack with
the two M-5 pan head T-25 Torx
®
screws, included with the Arm.
See Figure 8-12.
6. Extend the HP NetServer out of the rack to ensure the Cable Management
Arm moves along with the chassis without binding.
7. Plug the HP NetServer’s power cable and any available data cables into the
back of the HP NetServer.
NOTE
Refer to the HP NetServer LXr 8500 Rack Assembly and
Cabling Reference Guide for information about cable dressing
and routing.
8. Dress the cables in the Cable Management Arm and then slide the HP
NetServer into the rack to verify the cables don’t bind in the tray.