Deployment_B
•
Any additional management networks that you have created for side B
e Select the Untagged checkbox for the Deployment_B network.
4 Click to create the vMotion_FT_Set_A network set:
a Name: vMotion_FT_Set_A.
b Preferred Bandwidth: 2 Gb/s.
c Maximum Bandwidth: 20 Gb/s.
d Click Add networks and add the following networks to this network set:
•
vMotion_A
•
FT_A
•
Any additional vMotion and fault tolerance networks that you have created for side A
5 Click to create the vMotion_FT_Set_B network set:
a Name: Motion_FT_Set_B.
b Preferred Bandwidth: 2 Gb/s.
c Maximum Bandwidth: 20 Gb/s.
d Click Add networks and add the following networks to this network set:
•
vMotion_B
•
FT_B
•
Any additional vMotion and fault tolerance networks that you have created for side B
6 Click to create the VM_Traffic_Set_A network set:
a Name: VM_Traffic_Set_A.
b Preferred Bandwidth: 9 Gb/s.
c Maximum Bandwidth: 20 Gb/s.
d Click Add networks and add the following networks to this network set:
•
VM_Traffic_A
•
Any additional VM traffic networks that you have created for side A
7 Click to create the VM_Traffic_Set_B network set:
a Name: VM_Traffic_Set_B.
b Preferred Bandwidth: 9 Gb/s.
c Maximum Bandwidth: 20 Gb/s.
d Click Add networks and add the following networks to this network set:
•
VM_Traffic_B
•
Any additional VM traffic networks that you have created for side B
8 Click Create.
Create Logical Interconnect Groups
The steps for creating logical interconnect groups might vary depending on whether you use 10GbE or 40GbE
connections to the network switches.
Note
You can select different ports from the ports indicated in the procedure. Ensure that you select ports
that match the network and SAN topologies in the environment.