Fan locations
Drive bay numbering
CAUTION:
To prevent improper cooling and thermal damage, do not operate the chassis unless all bays are
populated with a component or a blank.
NOTE:
A SATA or mini-SAS cable must be installed in a node for the node to correspond to drives in the
chassis.
HPE Apollo r2200 Chassis drive bay numbering
One 1U node corresponds to a maximum of three low-profile LFF hot-plug drives.
• Node 1 corresponds to drive bays 1-1 through 1-3.
• Node 2 corresponds to drive bays 2-1 through 2-3.
• Node 3 corresponds to drive bays 3-1 through 3-3.
• Node 4 corresponds to drive bays 4-1 through 4-3.
One 2U node corresponds to a maximum of six low-profile LFF hot-plug drives.
• Node 1 corresponds to drive bays 1-1 through 2-3.
• Node 3 corresponds to drive bays 3-1 through 4-3.