HPE Apollo r2600 Chassis drive bay numbering
One 1U node corresponds to a maximum of six SFF SmartDrives.
• Node 1 corresponds to drive bays 1-1 through 1-6.
• Node 2 corresponds to drive bays 2-1 through 2-6.
• Node 3 corresponds to drive bays 3-1 through 3-6.
• Node 4 corresponds to drive bays 4-1 through 4-6.
If a P840 Smart Array controller is installed, one 2U node corresponds to a maximum of twelve SFF
SmartDrives.
• Node 1 corresponds to drive bays 1-1 through 2-6.
• Node 3 corresponds to drive bays 3-1 through 4-6.
If using the Dynamic Smart Array B140i Controller, HPE H240 Host Bus Adapter, or HPE P440 Smart Array
Controller: one 2U node corresponds to a maximum of eight SFF SmartDrives. The remaining drives bays
must be populated with drive blanks.
• Node 1 corresponds to drive bays 1-1, 1-2, 1-4, 1-5, 2-1, 2-2, 2-3 and 2-5.
• Node 3 corresponds to drive bays 3-1, 3-2, 3-3, 3-5, 4-1, 4-2, 4-4 and 4-5.
HPE Apollo r2600 Chassis drive bay numbering
141
Summary of Contents for Apollo 2000 System
Page 14: ...14 Customer self repair ...
Page 15: ...Customer self repair 15 ...
Page 16: ...16 Customer self repair ...
Page 17: ...Customer self repair 17 ...
Page 43: ... 1U right rear I O blank 2U rear I O blank Removal and replacement procedures 43 ...
Page 54: ... Intel Xeon Phi Coprocessor 5110P AMD FirePro S9150 GPU 54 Removal and replacement procedures ...
Page 57: ... AMD FirePro S9150 GPU AMD FirePro S7150 GPU Removal and replacement procedures 57 ...
Page 59: ... NVIDIA GRID K2 GPU Intel Xeon Phi Coprocessor 5110P Removal and replacement procedures 59 ...
Page 60: ... AMD FirePro S9150 GPU AMD FirePro S7150 GPU 60 Removal and replacement procedures ...