properly
.
If
this
message
appears
,
check
that
the
external
frequency
reference
is
correctly
connected
to
the
EXT
REF
INPUT
.
(U)
and
(H)
SOFTKEY
O
VFL
Softkey
nesting
exceeds
the
maximum
number
of
levels
.
(U)
SRQ
The
specied
service
request
is
active
.
(M)
STEP
GAIN/A
TTN
F
AIL
Indicates
the
step
gain
has
failed.
(H)
T
ABLE
FULL
Indicates
the
upper
or
lower
table
of
limit
lines
contains
the
maximum
number
of
entries
allowed.
A
dditional
entries
to
the
table
are
ignored.
(U)
TG
SIGNAL
NOT
FOUND
Indicates
the
tracking
generator
output
signal
cannot
be
found.
F
or
the
receiver
RF
section,
check
that
the
TRA
CKING
GENERA
TOR
OUTPUT
is
connected
to
the
RF
INPUT
connector
with
an
appropriate
cable
.
F
or
the
EMI
receiver
,
check
that
the
cable
between
the
TRA
CKING
GENERA
TOR
OUTPUT
and
TRA
CKING
GENERA
TOR
is
properly
connected.
(U)
TG
UNL
VL
This
message
can
indicate
the
following:
that
the
source
power
is
set
higher
or
lower
than
the
instrument
can
provide
,
that
the
frequency
span
extends
beyond
the
specied
frequency
range
of
the
tracking
generator
,
or
that
the
calibration
data
for
the
tracking
generator
is
incorrect.
(U)
T
oo
many
open
les
This
error
may
be
due
to
conicting
disk
operations
invoked
from
the
front-panel
keys
and
the
remote
I/O
port,
or
it
may
indicate
that
the
disk
is
corrupt.
After
pressing
the
\HOLD"
key
,
4
(ENTER)
5 ,
on
the
front
panel,
retry
the
operation.
If
the
operation
fails
again,
check
the
disk
using
the
catalog
function.
(U)
T
oo
many
signal
with
valid
N
dB
points
Indicates
the
N
dB
PTS
function
has
located
two
or
more
signals
that
have
amplitudes
within
the
specied
dB
from
the
signal
peak.
If
this
happens
,
you
should
decrease
the
span
of
the
instrument
so
that
only
the
signal
that
you
want
to
measure
is
displayed.
(U)
Trace
A
is
not
available
Indicates
that
trace
A
is
in
the
store-blank
mode
and
cannot
be
used
for
limit-line
testing.
Use
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CLEAR
WRITE
A
or
NNNNNNNNNNNNNNNNNNNN
VIEW
A
to
change
trace
A
from
the
store-blank
mode
to
the
clear
write
mode
,
and
then
turn
on
limit-line
testing.
(U)
Unable
to
replace
le
Reported
if
an
attempt
is
made
to
append
data
to
a
le
and
the
le
cannot
be
extended.
Try
the
operation
using
another
disk.
(U)
USING
DEF
A
UL
TS
self
cal
needed
Indicates
that
the
current
correction
factors
are
the
default
correction
factors
and
that
the
self-calibration
routines
need
to
be
performed.
F
or
either
an
HP
8546A
or
an
HP
85462A,
also
perform
the
NNNNNNNNNNNNNNNNNNNNNNN
CAL
YTF
self-calibration
routine
.
(U)
13-12
Error