![HP 64700 series User Manual Download Page 246](http://html.mh-extra.com/html/hp/64700-series/64700-series_user-manual_161481246.webp)
1
sample
This command specifies the sampling period or rate.
Syntax
Function
The sample command sets the sampling period or rate for
subsequent measurements. Data is acquired by the analyzer and
stored in trace memory at that effective rate.
Default Values
The default is the fastest sample rate in each mode.
Parameters
period_is
This option specifies the sample rate based
on the period.
< PER IOD>
This prompts you to enter the length of the
sample period. The allowed range is 10 nsec
(20 nsec in glitch_capture mode) to 500 msec.
nsec,
usec,
msec
These parameters specify the units of
measurement of < PER IOD> in
nanoseconds, microseconds, or milliseconds,
respectively.
9-78 Timing: Commands
Summary of Contents for 64700 series
Page 2: ......
Page 19: ...Tables Table 9 1 Summary of Commands 9 4 Table 9 2 Command Assignments 9 5 Contents 11 ...
Page 20: ...1 Notes 12 Contents ...
Page 24: ...1 Notes 1 4 Introduction ...
Page 106: ...1 Notes 4 36 Performance Measurements ...
Page 118: ...Figure 5 8 True Demultiplexing 5 12 Using the External Analyzer ...
Page 128: ...1 Notes 6 6 Timing Introduction ...
Page 134: ...1 Notes 7 6 Timing Getting Started ...
Page 168: ...1 Notes 8 34 Timing Using the Analyzer ...
Page 201: ...1 find This command finds a trigger like event in trace memory Syntax Timing Commands 9 33 ...
Page 219: ...1 mark This command marks specified conditions in trace memory Syntax Timing Commands 9 51 ...
Page 254: ...1 trigger This command specifies trigger conditions Syntax 9 86 Timing Commands ...
Page 262: ...1 Notes 9 94 Timing Commands ...
Page 280: ...1 Notes B 16 Timing Diagrams and Outputs ...
Page 292: ...1 Notes C 12 Timing Messages ...