STORE
&
RECALL
The 3314A has 12 Waveforms storage registers, six for non
-ARB
waveforms and six
for ARB waveforms
.
For non-ARB waveforms
,
register 0 automatically
r
et ains the cur
-
rent front panel settings at power off; registers 1 through
5
are reserved for the operator
.
The ARB registers
0
through
5
store waveforms as they are built in them. The contents
of all 12 registers, stored in non
-volatile
memory are retained whenever power is turn-
ed off.
How to Store and Recall Front Panel Settings
You can store the current (non-ARB) settings using the STO key followed by one
of the keys in the top row of the Entry key group. The register number where the
settings will be stored are located to the upper right of each key. To recall a front
panel, use the RCl key followed by one of the Entry keys. RCl 0 will recall the
front panel setting when the 3314A last lost power or was turned Off. Note that
if a series of power failures occurs, you will still be able to recover the last front
panel setting you used.
How to Recall ARB Waveforms
There are 6 ARB waveforms stored in the 3314A. The wave parameters are
stored into the proper ARB register as the waveform is created. There is no key or
command to store an ARB waveform. To recall a waveform, use the RCL and ARB
keys, followed by one of the keys in the
·
Ent ry Group. The number to the upper
right of each
indicates the ARB wave that will be recalled. The 3314A will
display • Arx· for 1/2 second to indicate which ARB wave was recalled.