![hotset hotcontrol cDT+ Start-Up, Service And Operation Manual Download Page 189](http://html1.mh-extra.com/html/hotset/hotcontrol-cdt/hotcontrol-cdt_start-up-service-and-operation-manual_2170222189.webp)
Hotset GmbH
187
Start-up-, Service- and Operation Manual hotcontrol cDT+
Rev. 1.00.05
Subject to technical changes
19.1 HTC 06/15 Heating Thermocouple Card - Replace fuses
Identify component.
Working on
hotcontrol cDT+
is only allowed in de-
energized status of
hotcontrol cDT+
.
Working on
hotcontrol cDT+
may be carried out by
authorized and skilled qualified personnel only.
Fuse for heating
Use ONLY fuses of type SIBA FF 16A Art.No. 7012540.16!
The action concerning the handling of ESD devices must be observed!
Electrostatic sensitive devices!
Deenergize hot runner controller.
Unlock and open front door by double bit lock.
Desktop housing
Cards count at
hotcontrol cDT+
desktop housing from
right to left
.
hotcontrol cDT+
DIP
ON
DEC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
..
.
DIP switch setting (binary coded)
1
2
3
4
5...
4 3 2 1