Start-up-, Service- and Operation Manual hotcontrol cDT+
Rev. 1.00.05
Subject to technical changes
18.1.7Sensor inputs and power outputs (Output plug XA*)
Connect the thermocouples TC of type J, L, K to the sensor inputs and heaters to the control outputs of the con-
nection of hot runner mold.
18.1.8Power Supply
The hot runner controller is activated/deactivated by the main switch (desktop housing rear wall ).
Consider terminal assignment (see specifications / wiring diagram).
The cable cross sections of all connecting cables must be installed, based on valid national
standards of the installation location and according to the appropriate type of use in each
country. Consider the maximum ambient temperature at selection of cables.
The connecting cables for power outputs / heaters may only be connected in de-energized
status.
The connecting cables must be designed for an operating voltage of 250VAC and overvolt-
age category II.
At the plug contacts of the output plugs XA * can be a dangerous voltage in the on-state.
The hot runner controller may be installed and put into operation by specialized staff only.
Before switch-on of the control zones it is to be ensured that the hot runner controller is config-
ured for the application. An incorrect configuration can lead to damage to the control section or
to injuries to persons.
Consider connected load.
Check the power supply under the terms of the wiring diagram