6.3
Standby
Description
In Standby mode the setpoint values are reduced, because e.g. in production breaks
it makes sense, to reduce the temperature level of the hot runner.
How it works
At operation the Standby mode is started and ended at the push of the button. The
setpoint values of the zones are reduced by a freely selectable temperature value.
Alternatively the function can also be activated by a digital input e.g. from the injection
molding machine.
What good is it
Energy is saved and the plastic, located in the cavities, is not thermally damaged.
Setting by
[SP11]Auto Standby Time (page 193)
[P007]Standby setpoint value (page 191)
For further details on parameters ([P***], [SP**], [CP**]) see Manual Parameters
hot-
control cDT+
.
Whether and which keys are activated
for the user, see chapter
Press key
After activation of the Standby
function, all zones are reduced
by the setpoint value under pa-
rameter
Reject
Confirm
In the first line of the zone display, the display of the text alternates with
the display of the current value (see chapter
Standby function active is sig-
nalized by the green color in
the key.