GB
27
N
L
2. Install the power supply
cable by loosening the cable
clamp screw and the three
w i r e c o n t a c t s c r e w s
L-N-
.
Connect the wires to the
corresponding terminals:
the Blue wire to the terminal
marked (N), the Brown wire
to the terminal marked (L)
and the Yellow/Green wire
to the terminal marked
(see diagram).
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate (see table).
The appliance must be directly connected to the mains using
an omnipolar switch with a minimum contact opening of 3
mm installed between the appliance and the mains. The
switch must be suitable for the charge indicated and must
comply with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply cable
must be positioned so that it does not come into contact
with temperatures higher than 50°C at any point (the back
panel of the oven, for example).
!
The installer must ensure that the correct electrical
connection has been performed and that it is fully compliant
with safety regulations.
Before connecting the appliance to the power supply, make
sure that
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate.
• The voltage is in the range between the values indicated
on the data plate.
• The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
!
Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
!
The cable must not be bent or compressed.
!
The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
!
The manufacturer declines any liability should these
safety measures not be observed.
APPLIANCE SPECIFICATIONS
Dimensions*
width 43.5 cm
height 41 cm
depth 41 cm
Volume*
74 l
Dimensions**
width 45.6 cm
height 41 cm
depth 41 cm
Volume**
77 l
Electrical
connections
voltage: 220 - 240 V~ 50/60Hz or
50Hz maximum power absorbed
2600 W (see data plate)
ENERGY LABEL
Directive 2002/40/EC on the
label of electric ovens.
Standard EN 50304
Declared energy consumption
for Forced convection
Class – heating mode:
ECO.
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments – 2004/108/EEC
dated 15/12/04
(Electromagnetic
Compatibility) and subsequent
amendments - 93/68/EEC
dated 22/07/93 and
subsequent amendments.
2012/19/EEC and subsequent
amendments.
1275/2008 Stand-by/off mode
* Only for models with drawn rails.
** Only for models with wire rails.