Service and Maintenance / Disassembly the Nozzle 16S-06 / 22S-0S Series
Disassembly the Nozzle Tip
Hazard of Pressurized Air
Pressurized air blow can result in hot plastic or foreign bodies entering the
eyes, causing vision damage.
Following work must be carried out by qualified and experienced persons.
Use personal protective equipment: Face protection, hearing protection and
gloves.
For first aid contact your medical / safety representing.
NOTICE
To install or remove the nozzle tip (8), the tool holder (T2) and
adapter (T1) is required.
The nozzle head can get damaged when we do not use these
tools.
Only with the tools holder (T2) and adapter (T1) it is ensured
that the nozzle body (1) is attached properly torqued to the hot
runner manifold.
1) The nozzle head heater (13) must be dismounted from the nozzle head
(11), as described in the above page 592.
2) Fix the holder (T2) in a vice.
Doc006751.png
3)
Place the nozzle with the head (11) in the holder (T2) to fix the nozzle
against rotation.
Doc008832_RIS.png