DEFROST PROCESS
FREEZE PROCESS
Water Pan
Water Pan
OPEN
CLOSED
ON
A MODE
Approx. 15 sec.
Approx. 60 sec. [240ME/WME]
(90 sec. at start up)
ON
OFF
ON
B’ MODE
Approx. 15 sec.
1234
1234
123456789012345
123456789012345
b. IM-100LE/WLE, IM-130LE/WLE, IM-130ME/WME, IM-160ME, IM-240ME/WME, IM-
240M2E/WM2E
Note: In some areas where excessively hard water (approx. 250 ppm or more) results in
production of cloudy ice, change the water supply time setting as follows.
Cut the jumper wire JE (marked by arrow) by
a nipper. Water supply time will be 60 sec.
when the Water Plate is closed.
The jumper wire JE for IM-240ME/WME
(except IM-240M2E/WM2E) has already
been cut at factory adjustment.
Normal setting = 15 sec. with Water Plate closed
Controller Board
Mode
Model
C10
B’
IM-21CLE, IM-25LE, IM-25CLE, IM-30CLE,
IM-45LE, IM-45CLE-25, IM-65LE
C12
B’
IM-25WLE, IM-30WLE, IM-45WLE, IM-65WLE
C02
A
IM-100LE, IM-130LE, IM-130ME, IM-160ME
C03
A
IM-100WLE, IM-130WLE, IM-130WME
IM-240ME, IM-240WME, IM-240M2E, IM-240WM2E
Summary of Contents for IM-100
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Page 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Page 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Page 8: ...4 d IM 45LE Air cooled ...
Page 9: ...5 e IM 45CLE 25 Air cooled ...
Page 10: ...6 f IM 65LE Air cooled ...
Page 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Page 12: ...8 h IM 100CLE Air cooled ...
Page 13: ...9 i IM 160ME Air cooled ...
Page 14: ...10 j IM 240ME Air cooled ...
Page 15: ...11 k IM 240M2E Air cooled ...
Page 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Page 17: ...13 m IM 45WLE Water cooled ...
Page 18: ...14 n IM 65WLE Water cooled ...
Page 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Page 20: ...16 p IM 240WME Water cooled ...
Page 21: ...17 q IM 240WM2E Water cooled ...
Page 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Page 71: ...67 b IM 25L IM 25CL IM 25WL ...
Page 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Page 73: ...69 d IM 65LE IM 65WLE ...
Page 74: ...70 e IM 65L IM 65WL ...
Page 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 80: ...76 k IM 160ME ...
Page 81: ...77 l IM 240ME IM 240WME ...
Page 82: ...78 m IM 240M2E IM 240WM2E ...
Page 120: ...116 Fig 30 ...