58
Fig. 22
10) As soon as the Water Pan closes, pour the cleaning solution prepared in 1) carefully into
the Water Pan. Do not splash or spill the solution onto the other parts.
11) Circulate the cleaning solution for 30 minutes. Open the water supply tap, and repeat the
above steps 6) and 7).
12) When the Water Pan closes again, circulate water for 5 minutes. For IM-100/130/160/
240 only, pour clean water into the Water Pan until it floods from the Overflow Pipe.
13) Repeat the above steps 6), 7) and 12) at least three times to rinse thoroughly.
SANITIZING INSTRUCTIONS
Note: Sanitizing should always be completed after cleaning or alternately as an individual
procedure if conditions exist to make it necessary.
14) Use a suitable container to dilute 5.25% sodium hypochlorite solution into the following
concentration:
IM-21 - 65
Mix 15 ml of the sodium hypochlorite solution with 3.8 litres of water.
IM-100/130/160
Mix 30 ml of the sodium hypochlorite solution with 7.6 litres of water.
IM-240
Mix 44 ml of the sodium hypochlorite solution with 11.4 litres of water.
* Alternatively use the Hoshizaki recommended sanitizer as directed by the relevant
instructions.
15) Repeat the above steps 5), 6) and 7), and close the water supply tap.
16) As soon as the Water Pan closes, pour the sanitizing solution prepared in 14) carefully
into the Water Pan. Do not splash or spill the solution onto the other parts.
17) Circulate the solution for 15 minutes. Open the water supply tap, and repeat the above
steps 6) and 7).
18) When the Water Pan closes again, circulate water for 5 minutes. For IM-100/130/160/
240 only, pour clean water into the Water Pan until it floods from the Overflow Pipe.
19) Repeat the above steps 6), 7) and 18) at least three times to rinse thoroughly.
20) Move the Tank Drain Pipe to the normal position, and secure it with
the screw. See Fig. 13. (IM-100/130/160/240 only)
21) Repeat the above steps 6) and 7) again. When the icemaker stops,
move the Washing Switch to the “ICE” position. See Fig. 22. (The
Summary of Contents for IM-100
Page 5: ...1 I SPECIFICATIONS 1 DIMENSIONS CONNECTIONS a IM 25LE Air cooled ...
Page 6: ...2 b IM 25CLE Air cooled Until March 2000 production Auxiliary Code K 1 ...
Page 7: ...3 c IM 21CLE IM 25CLE IM 30CLE Air cooled From April 2000 production Auxiliary Code K 2 ...
Page 8: ...4 d IM 45LE Air cooled ...
Page 9: ...5 e IM 45CLE 25 Air cooled ...
Page 10: ...6 f IM 65LE Air cooled ...
Page 11: ...7 g IM 100LE IM 130LE IM 130ME Air cooled ...
Page 12: ...8 h IM 100CLE Air cooled ...
Page 13: ...9 i IM 160ME Air cooled ...
Page 14: ...10 j IM 240ME Air cooled ...
Page 15: ...11 k IM 240M2E Air cooled ...
Page 16: ...12 l IM 25WLE IM 30WLE Water cooled ...
Page 17: ...13 m IM 45WLE Water cooled ...
Page 18: ...14 n IM 65WLE Water cooled ...
Page 19: ...15 o IM 100WLE IM 130WLE IM 130WME Water cooled ...
Page 20: ...16 p IM 240WME Water cooled ...
Page 21: ...17 q IM 240WM2E Water cooled ...
Page 70: ...66 2 WIRING DIAGRAM a IM 21CLE IM 25LE IM 25CLE IM 30CLE IM 25WLE IM 30WLE ...
Page 71: ...67 b IM 25L IM 25CL IM 25WL ...
Page 72: ...68 c IM 45LE IM 45CLE 25 IM 45WLE ...
Page 73: ...69 d IM 65LE IM 65WLE ...
Page 74: ...70 e IM 65L IM 65WL ...
Page 76: ...72 g IM 130LE IM 130WLE Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 78: ...74 i IM 130ME IM 130WME Note The Washing Switch is provided only after the Auxiliary Code H 0 ...
Page 80: ...76 k IM 160ME ...
Page 81: ...77 l IM 240ME IM 240WME ...
Page 82: ...78 m IM 240M2E IM 240WM2E ...
Page 120: ...116 Fig 30 ...