76
[Water-cooled Models]
1) Turn off the power supply and wait for 3 minutes.
2) Turn on the power supply and wait for 20 seconds.
3) Close the Water Supply Line Shut-off Valve.
4) Open the Drain Valve and quickly blow the water supply line from the Drain Valve to drain
water in the Condenser.
5) Follow the above steps 3) through 11) in [Remote Air-cooled Models].
2. CLEANING INSTRUCTIONS
IMPORTANT
Ensure all components, fasteners and thumbscrews are securely in place after any
maintenance or cleaning is done to the equipment.
WARNING
1. HOSHIZAKI recommends cleaning this unit at least once a year. More fre-
quent cleaning, however, may be required in some existing water
conditions.
2. To prevent injury to individuals and damage to the icemaker, do not use
ammonia type cleaners.
3. Always wear liquid-proof gloves for safe handling of the cleaning and
sanitizing solution. This will prevent irritation in case the solution comes
into contact with skin.
<STEP 1>
Dilute the solutions with water as follows.
Cleaning solution: 4.8 fl. oz. of recommended cleaner Hoshizaki “Scale Away” or
“LIME-A-WAY” (Economics Laboratory, Inc.) with 0.8 gal. of water.
This is a minimum amount. Make more solution, if necessary.
Sanitizing solution:
2.5 fl. oz. of a 5.25 % sodium hypochlorite solution (chlorine bleach) with
5 gal. of water.
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...