![Hoshizaki F-2000MLH Service Manual Download Page 49](http://html1.mh-extra.com/html/hoshizaki/f-2000mlh/f-2000mlh_service-manual_2165109049.webp)
49
IV. ADJUSTMENT OF COMPONENTS
1. ADJUSTMENT OF WATER REGULATING VALVE - WATER-COOLED
MODEL ONLY
The Water Regulating Valve or also called “WATER REGULATOR” is factory-adjusted. No
adjustment is required under normal use. Adjust the Water Regulator , if necessary, using
the following procedures.
1) Attach a pressure gauge to the high-side line of the system. Or prepare a thermometer
to check the condenser drain temperature.
2) Rotate the Adjustment Screw by using a flat blade screwdriver, so that the pressure
gauge shows 260 PSIG (R-404A models/-F type), or the thermometer reads 100 -104°F,
in 5 minutes after the icemaking process starts. When the pressure exceeds 230, 215,
or 260 PSIG, or the condenser drain temperature exceeds 104°F, rotate the Adjustment
Screw counterclockwise.
3) Check that the pressure or the condenser drain temperature holds a stable setting.
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...