5
I. SPECIFICATION
1. ICEMAKER
F-2000MWH
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
COMPRESSOR
240 V
10.8 RLA
96 LRA
GEAR MOTOR
120 V
5.6 FLA
0.54 HP
FAN MOTOR
120 V
0.51 FLA
8W
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
30 A
MAX. HACR BREAKER (USA ONLY)
30 A
MAX. CIRC. BREAKER (CANADA ONLY)
30 A
MINIMUM CIRCUIT AMPACITY
30 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*2030 (921)
1955 (887)
1915 (869)
Reference without *marks
80
1875 (851)
1835 (832)
1795 (814)
90
1760 (798)
*1730 (785)
1685 (764)
100
1650 (748)
1615 (733)
*1500 (680)
SHAPE OF ICE
Flake
ICE QUALITY
Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2510 (3.5)
2490 (2.9)
POTABLE WATER
207 (12)
243 (12)
WATER-COOLED CONDENSER
1165 (67)
735 (36)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 310 lbs. ( 140 kg ), Shipping 342 lbs. ( 155 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
Cond. Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
Cond. Outlet 1/2" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 400 W Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
Automatic Water Regulator
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model CS20-K6E-PFV
CONDENSER
Water-cooled, Tube in tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
2 lbs.
(910g)
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Internal Protector
GEAR MOTOR PROTECTION
Manual Reset Circuit Breaker & Thermal Protector
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
BIN CONTROL PROTECTION
Manual Reset Spout Control
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
187-253 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...