3. ADJUSTMENT OF EVAPORATOR PRESSURE REGULATOR (E.P.R) -
F-2000MLH/-C ONLY
The Evaporator Pressure Regulator (E.P.R) prevents the evaporator pressure from
dropping below the pressure setting of 22 PSIG (R-404A model (-F type). Adjust the setting,
if necessary, according to the following instructions:
1) Remove the Cap from the E.P.R. Access Valve, and connect a pressure gauge (The
E.P.R. needs no adjustment if the pressure gauge shows 22 PSIG for F-2000MLH/-C.)
2) Remove the Cover from the E.P.R., and rotate the Adjustment Screw by a hexagon
wrench until the pressure gauge shows 22 PSIG (F-2000MLH/-C). Rotate clockwise to
increase the pressure setting, and rotate counterclockwise to decrease the pressure
setting.
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...