![Hoshizaki F-2000MLH Service Manual Download Page 10](http://html1.mh-extra.com/html/hoshizaki/f-2000mlh/f-2000mlh_service-manual_2165109010.webp)
10
F-2000MRH3-C
We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE
208-230/60/3
COMPRESSOR
240 V
9.0 RLA
75 LRA
GEAR MOTOR
120 V
5.6 FLA
0.54 HP
FAN MOTOR REMOTE
120 V
3A
MAX
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*1725 (782) 1685 (764) 1650 (748)
Reference without *marks
80
1615 (733) 1580 (717) 1545 (701)
90
1515 (687) *1525 (692) 1450 (658)
100
1420 (644) 1390 (631) *1275 (578)
SHAPE OF ICE
Cubelet
ICE QUALITY
Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
3000 (4.6)
2970 (4.1)
POTABLE WATER
183 (12)
207 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 310 lbs. ( 140 kg ), Shipping 342 lbs. ( 155 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
- REFRIGERATION
Discharge line 1-1/16-12 UNF Fitting (#10 AEROQUIP)
CIRCUIT
Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 400 W Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model CS20-K6E-TF5
CONDENSER
Air-cooled Remote Condenser unit URC-20F Recommended
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-20F
REFRIGERANT CHARGE
R-404A, 14 lb. 9 oz. (6600g)
(Ice Maker: 6 lb. 14 oz., Cond. Unit: 7 lb. 11 oz. )
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Internal Protector
GEAR MOTOR PROTECTION
Manual Reset Circuit Breaker & Thermal Protector
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
BIN CONTROL PROTECTION
Manual Reset Spout Control
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
187-253 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...