11
F-2000MLH
AC SUPPLY VOLTAGE
115/60/1
GEAR MOTOR
120 V
5.6 FLA
0.54 HP
FAN MOTOR
120 V
0.51 FLA
8W
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
15 A
MAX. HACR BREAKER (USA ONLY)
15 A
MAX. CIRC. BREAKER (CANADA ONLY)
15 A
MINIMUM CIRCUIT AMPACITY
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*2280 (921)
1955 (887)
1915 (869)
Reference without *marks
80
2010 (851)
1835 (832)
1795 (814)
90
1900 (862)
*1730 (785)
1685 (764)
100
1650 (748)
1615 (733)
*1370 (680)
SHAPE OF ICE
Flake
ICE QUALITY
Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
470 (0.6)
490 (0.5)
POTABLE WATER
207 (12)
258 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
30" x 27-1/2" x 34-7/16" (762 x 699 x 874mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 216 lbs. ( 98 kg ), Shipping 250 lbs. ( 113 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
- REFRIGERATION
Suction line 1-1/16-12 UNF Fitting (#10 AEROQUIP)
CIRCUIT
Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 400 W Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
CONDENSING UNIT
Required capacity for ice maker is 11600 BTU/h at discharge
pressure 221 PSIG and suction pressure 22 PSIG with R404A
refrigerant.
Suction pressire needs to be less than 22 PSIG.
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Evaporator Pressure Regulator
REFRIGERANT CHARGE
R-404A,
3.5 oz. (100g)
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
GEAR MOTOR PROTECTION
Manual Reset Circuit Breaker & Thermal Protector
LOW WATER PROTECTION
Float Switch and Timer
BIN CONTROL PROTECTION
Manual Reset Spout Control
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104-127 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
We reserve the right to make changes in specifications and design without prior notice.
Summary of Contents for F-2000MLH
Page 13: ...13 2 CONDENSER UNIT URC 20F...
Page 15: ...15 II GENERAL INFORMATION 1 CONSTRUCTION F 2000MWH C...
Page 16: ...16 F 2000MRH C F 2000MRH3 C...
Page 17: ...17 F 2000MLH C...
Page 19: ...19 F 2000MRH3 C...
Page 20: ...20 F 2000MLH C...
Page 21: ...21 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 2000MWH C...
Page 22: ...22 F 2000MRH C F 2000MRH3 C...
Page 23: ...23 F 2000MLH C...
Page 24: ...24 2 WIRING DIAGRAMS F 2000MWH C...
Page 25: ...25 F 2000MRH C...
Page 26: ...26 F 2000MRH3 C...
Page 27: ...27 F 2000MLH C...
Page 29: ...29 b When Reservoir has been filled Gear Motor starts immediately...
Page 32: ...32 e Low Water Except Water cooled Model where Compressor will operate intermittently...
Page 38: ...38...
Page 68: ...68...