52
(3) SENSOR BOARD
1) Remove the plastic covers from the operation panel unit.
2) Disconnect the flexible cable from the connector on the operation board.
3) Remove the self cover and operation panel.
4) Unscrew the motor bracket, and remove the gear motor together with the motor bracket.
5) Pull the tap plate assembly out of the operation panel unit.
* Be careful not to damage the flexible cable.
6) To replace, reverse the above procedure.
* See the instructions of “(4) FLEXIBLE CABLE”.
(4) FLEXIBLE CABLE
To remove:
1) Pull the flexible cable connector in the direction perpendicular to the operation board to unlock
(see the figure below). The coating may have stuck to the operation board.
2) Pull the flexible cable off the connector.
Cover (B)
Self Cover
Operation Panel
Motor Bracket
Tap Motor Assembly
Tap Plate Assembly
Sensor Board
Ribbon Cord Holder
Flexible Cable
Unlock connector
Disconnect flexible cable
Connector
Flexible Cable