12
c. User Settings – The user can adjust these settings.
To enter the setting mode:
Press and hold the set button for 3 seconds.
To enter the dispensing mode:
With “U_ _” on the display, press and hold the set button for 3 seconds. The dispensing mode is
also resumed if no operation is performed for more than 1 minute.
Item
Description
Default
Setting
Range
U01
Digital display
(in dispensing
mode)
0: No indication
1: Number of mugs (*)
* Number switches between the larger and smaller mugs when
the mug setting is changed.
* To reset, press and hold the stop button for 3 seconds.
0
0 to 1
U02
Log of number
of mugs
Log of number of mugs for each reset in descending
order
* Log is indicated in turn for each keg replacement by “U04”.
* Log is indicated for both larger and smaller mugs when the
mug setting is changed.
* To reset all the current and past logs, press and hold the stop
button for 3 seconds. This reset is not counted for “U04”. (*1)
0
Up to
5 logs
U03
Number of flush
cycles
Number of flush cycles performed
* A flush cycle consists of liquid button operation (total 10
seconds) + foam button operation (total 3 seconds) in the
flush mode except when no automatic dispensing action is
made during the cycle.
* To reset, press and hold the stop button for 3 seconds.
0
0 to
9999
U04
Number of keg
replacements
(reset
frequency)
Reset frequency for number of mugs
(*2)
* Keg replacement is counted every time the number of kegs is
reset by the stop button operation.
* To reset, press and hold the stop button for 3 seconds.
0
0 to
9999
U05
Dispense lamp
brightness
Adjustment of dispense lamp brightness
6
1 to 8
U06
Dispense lamp
flashing
duration
Adjustment of dispense lamp flashing duration after
completion of dispensing
* The dispense lamp flashes to prevent another mug is placed
while foam is still dripping.
* Automatic dispensing action is not available while the lamp is
flashing.
1
0 to 10