28
Beer
(2) No beer is dispensed
Possible Cause
Remedy
1. Frozen beer cooling line.
1-1 Damaged controller board.
1-2 Electrode out of position.
Electrode is too close to beer coil.
1-3 Dirty cooling water (mixture of beer in
water tank causes freezing).
1-1 See instructions for handling controller board.
(See (18) of “9. SERVICE DIAGNOSIS”.)
1-2 Reposition electrode. (See “10. Parts”.)
1-3 Cooling water mixed with beer will be entirely frozen.
Repair leaks and replace cooling water.
2. Beer tap will not move smoothly.
2-1 Valve shaft sliding failure.
2-2 Abrasion powder in spherical lever
bearing.
2-1. Disassemble and clean beer tap. Completely deburr
beer tap. Especially deburr and chamfer edge of
lever insert hole in valve shaft sliding part.
2-2. Remove lever from beer tap to polish spherical
bearing.
3. No CO2 gas in beer keg.
3-1 Empty CO2 gas cylinder.
3-2 Closed main valve of CO2 gas cylinder.
3-3 Closed keg coupler handle.
3-1 Replace CO2 gas cylinder.
3-2 Open main valve of CO2 gas cylinder.
3-3 Open keg coupler handle.
4. Beer circuit clogged with cleaning
sponge or foreign matter.
4. Flush from beer tap to unclog beer circuit.
5. Empty beer keg.
5. Replace beer keg.
(3) Beer will not stop
Possible Cause
Remedy
1. Rubber seal fell off beer tap valve shaft.
1. Disassemble beer tap and attach rubber seal on valve
shaft.
2. Beer tap valve shaft cannot return to
original position.
Valve shaft sliding failure.
2. Disassemble and clean beer tap. Completely deburr
beer tap. Especially deburr and chamfer edge of lever
insert hole in valve shaft sliding part.
3. CO2 gas pressure too low.
3. Adjust CO2 gas pressure to proper level.
The chart below is general example.
Adjust to gas pressure specified by beer manufacturer.
Temperature of beer keg CO2 gas pressure
10°C
0.20MPa
20°C
0.22MPa
30°C
0.32MPa