17
A31
Coin mechanism
type 1
Not in use
0
0, 1
A32
Coin mechanism
type 2
Not in use
0
0, 1
A40
Foam button
operation to
reset sold out
Duration to press and hold foam button to cancel
sold out
* Need to press foam button once even if set to 0
sec
0
0 to 20 /
1
A80 Adjust mode
Not in use
0
0 to
9999 / 1
A90
Reset settings
(user settings)
Same as “U90”
0
0, 1
A91
Reset settings
(check mode &
adjust mode)
Initialize check mode and adjust mode settings to
defaults
With “1” on display, press and hold stop button for 3
sec --> “A91” on display
* “C03” error log will also be deleted
* “U02” to “U04” logs and beer amount setting will
not be deleted
0
0, 1
A01: The platform tilt angle is adjustable to prevent a mug from touching the beer tap.
A02: As mentioned in (24) of “9. SERVICE DIAGNOSIS”, if the beer tap slider does not go back to
the center position to fit the tap handle, the motor must be removed to move the beer tap
slider back to the center position. While “A02” is selected, press the liquid/foam button to
move the beer tap slider to any position without removing the motor. Not used in normal
operation.
A03: Normally, the self mode is reset by lifting up the operation panel unit. If it cannot be moved,
use “A03” to reset the self mode.
A04: The administrator can check the dispensing operations canceled, for example, by customers
in the self mode.
A05 to A07:
The ice storage condition is checked by the electric conductivity of cooling water. The
threshold of the electric conductivity is adjustable. Not used in normal operation.
A08: The setting D of the user setting (U07) is adjustable.
A30 to A32:
Not used in normal operation.
A40: After keg replacement, if beer foam is not led to the beer tap enough, beer may splash out of
the beer tap. To prevent this, the foam button must be pressed and held for this duration to
cancel the sold out condition.
* The longer the duration is adjusted, the more beer is wasted to lead beer foam to the beer
tap. Customer approval is required before adjustment.
A80: Not in use.
A90, A91:
To leave the settings as they are and delete the logs (U02, U03, U04, C03) only, press and
hold the set and flush buttons, turn off the breaker, and turn it back on. The beer amount
setting will not be deleted.