Joining of hoppers
The seed wagon SW 12000 SD enables the
placement of the same medium from both hop-
pers.
¾
For this purpose open the flange connections
(1) of the pneumatic hoses on the metering
units.
¾
Install the supplied hoses (2) between the
fall sluices and fasten the flange connections
again.
¾
Adjust the valves on the air distribution hose
in such a way, that the two outermost outlets
are closed.
2
1
1
Pneumatic system conversion for hopper combination
1 Flange connections
2 Hoses for hopper combination
NOTE
¾
Check all connections for leak tightness.
Leaks lead to sowing faults.
The desired seed quantity can be manually
distributed in the E-Manager to both metering
units. The “Hopper combination” function is
additionally available.
In this context pay attention to the operating
instructions for the E-Manager.
56