Zone
type
→
40
→
XX
→
Y
→
Y #
Relay
output
→
42
→
XX
→
#
→
41
→
X
→
#
Relay
output
itme
Siren
sounding
when
arm
or
disarm
→
43
→
XX
→
#
→
44
→
X
→
#
XX=05 (50s)
X = 1
25
26
26
26
26
28
27
30
29
27
27
27
X = 1
X = 0
→
39
→ →
X
#
19
20
21
24
23
25
→
38
→
X
→
X
#
→
31
→
XXX
→
#
25
25
→
37
→
X
→
X
#
XX = 05
→
30
→
XXX
→
#
25
→
27
→ →
Y
→
X
#
→
26
→ →
Y
→
X
#
→
28
→ →
YY
→
X
#
→
29
→
XX
→
#
23
23
24
01
24
Relay
NC
or
NO
→
24
→
X
→
Y
→
#
→
25
→
X #
→
X=1
Y=1
23
23
0
31
27
Using
key
to
disarm
or
arm
→
45
→
→
Y
→
Z
→
XX
#
-
16
-
PROGRAMMING
14
15
16
17
18
No.
Operation
on
keypad
Setting
referring
page
Description
Default
Turning on/ off siren
Turning on/ off detecting siren
X=0 means turning off siren.
X=1: turning on siren
Y=0 means turning off detecting siren,
Y=1: tuning on detecting siren
Sending installing message
to user or not
X=0~1.
0 means off; 1: on
On/off detecting telephone
line, AC power and battery
X=1,means choosing telephone line;
X=2:choosing AC power;
X=3:choosing battery.
Y=1means on; Y=0:off
Turning on detecting
telephone line;
Tuning off detecting
AC power and battery
Protocol option
X=1~2 means the series number of CMS
Y=0~1:series number of protocol,
Y=0:Contact ID, Y=1:4 +1
Contact ID for
CMS1 and
CMS2
Message option thru GSM
X(X=1~4): series number of GSM
device; YY: message option
Lasting time of siren working
XX=00
~
30, unit: 1minute
Working time 0~30 minutes
XX=10,
10s
Exit delay time adjustment
XXX=000~300
Time delay 0~300 seconds
XXX=100,
100s
Entry delay time adjustment
XXX=000~300
Time delay 0~300 seconds
XX=040,
40s
22
25
X=3
X=3~9
→
34
→ →
X
#
Ring attempts thru a free of
charge of telephone line
Attempts to send the same
message to a CMS
XX=00~99, Attempts to send the
same message to a CMS
Setting period of sending
the same alarm by only
one wired zone
XX=00~99,
Unit: 10 seconds
XX = 03
30s
Siren works again or not
when only a zone alarms
more than two times
X=1 means the siren works again when
a zone alarms more than 2 times.
X=0:siren works only one time
XX=01
~
16(01~08: 8 wired zones,
09~16:8 wireless zones)
Y=01~09,81,82
7
th
and 8
th
zone
are tamper type.
The others are
perimeter type
X=0/1, 0 means NO; 1: NC
XX=00~99, not all figures can be set,
refer the detail of setting 42XX
XX=00,
none-use
XX=00~60; 00 means relay output
until disarm. For example XX=02
means relay output for 02 seconds
X
=
0:Siren keeps silence,
X
=
1: Siren sounds after arm or
disarm
XX means the series number of a
zone; Y:panel's action after zone
XX triggers; Z:panel acts by zone
XX triggers or recover.
3 means panel
stay-arm after
Zone XX triggers
Summary of Contents for LHD6001+
Page 1: ...LHD6001 ...
Page 2: ......
Page 3: ...INSTALLATION MANUAL Hybrid alarm system ...
Page 11: ......
Page 34: ......
Page 35: ......
Page 36: ......