Remote controller
1. Wireless remote controller have 4 keys which can achieve operations of arm away/stay, disarm and panic alarm
without user password. Press keys on the remote controller towards the control panel to perform corresponding
operations. Press the panic button for 2 seconds to trigger the alarm.
Panic
Arm stay
Arm
away
Disarm
Correct direction of the antenna
Wrong direction of the antenna (the remote should not point to
the vertical direction
of
antenna
of
panel)
.
-
6
-
Wooden
Wall
Panel
Transmitter
A
Concrete
wall
Please notice several things as below to make sure best receiving and transmitting
.
Install the panel in the middle of all the wireless devices;
Far away from the places with noise, magnetic interfering, such as the place with air conditioner, heater,
and electronic box,etc.
Shorten the distance between the panel and detector;
Try to make the obstacles as less as possible;
The concrete wall will shorten the distance between the receiver and transmitter.
Oper
Transmitter
B
Transmitter
A
Transmitter
B
2. Force Arm: If the zones except 24h zones are triggered, which are set type1 by command 47, the panel will
still arm by pressing the button on remote controller one more time after the first arm failure. After this
operation, the triggering zones will be automatically bypassed. After restore the zones, zone bypassing will
be automatically cancelled. Please note, the force arm couldn't activated if it is alarming or entry delaying.
3. When there is no keypad working with this system, one remote controller can be learned to NO8 remote to
check the status of this system. Press any button of this registered remote controller, the panel will beep one
time to show disarm status, and twice for Arm.
4. The users also can set by command 69 a remote controller to arm or disarm all the zones or arm some zones
by pressing button one time. Please this doesn't work for the zones without exit delay which will arm immediately.
5. If the remote controller is built with antenna, the usage should be what stated in the below pictures.
Summary of Contents for LHD6001+