Back
-
up
battery
connection
The control panel uses 12V/7.0Ah sealed lead-acid rechargeable battery as standby power.
There is a red and a black power cords with plugs in the master controller for standby
power connection. Connect the red power cord to the positive terminal of standby power
and the black power cord to the negative terminal of standby power.
Standby power is offered overload protection by fast-blow fuse F6(2A). If the fuse
opens, remove the short or overload condition, and then replace the fuse before restoring
power. Do not substitute a higher rated fuse.
The system checks automatically the state of battery. If disconnect to standby power or
voltage of standby power , the control panel will take operation of low-voltage, "Lowvoltage"
indicator on keypad will be on, and buzzer will chirp twice in every two minutesuntil chirps 15 times(30minutes).
Under AC powered, the panel will self-check the back-up battery once in every 15 minutes, and check all the
time under AC power disconnected situation.
Note
:
If
low
voltage
is
still
indicated
on the keypad after 24 hours charging, the battery might be out of use.
Keypad installation
TERMIALS
KDATA
GND
V_KEY
Terminals
V_KEY:
GND: GND
Power
KDATA:
Power input terminal on the keypad
Data line for communication between
keypad and the master controller
Connection between the wiring board of keypad
and the control panel: Connect V_KEY, KDATA
and GND port in the control panel to those in the keypad wiring board respectively, and fix them by screws.
Wiring
gate
Digram
of
rear
of
the
keypad
When
more
than
1
keypad
should
be
connected
,
different
address
should
be
setted
for
different
keypad
to
avoid
conflict
which
can
be
done
through
jumping
the
cap
on
the
rear
of
the
keypad
.
Do
the
setting
as
the
what
in
right
.
Keypad
address
1(NO1 keypad)
2(NO2 keypad)
3(NO3 keypad)
4(NO4 keypad)
-
12
-
Connect
the
keypad
to
the
terminals
in
the
panel
as
below
.
SYSTEM INSTALLATION
Battery
Sealed lead Acid Accumulator
1
2
ID
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Note: “ ON stands
for
on
and OFF for
off.
”
“
”
POWER
ARM
DISARM
PROG
PANIC
*
#
Away
Stay
Disarm
PROG
/
Panic