
Programming Function Blocks and Features
Video Recorder – User Manual
118
Table 4-26 Logic Operators
For this operator
Definition
if this is true
then Result is
AND
If all programmed inputs are ON,
Result is ON.
All programmed inputs are
ON(1)
ON(1)
OR
If at least 1 programmed input is ON,
Result is ON.
At least 1 programmed
input is ON(1)
ON(1)
XOR
Uses Inputs A and B only.
Input A is ON(1) and Input
B is OFF(0).
ON(1)
If one and only one input is ON, Result
is ON.
Input A is OFF(0) and Input
B is ON (1).
ON(1)
RESET/SET FF
Rising edge of Input A turns Result
ON.
Input A is ON(1).
ON(1)
(Reset/Set Flip-Flop)
Rising edge of Input B resets Result.
Input A is OFF(0) and Input
B is ON (1).
OFF(0)
Reset/Set FF
Input A
Input B
Result
TOGGLE/FF
Toggle Flip-Flop. Rising edge of Input
A inverts Result
Input A changes from
OFF(0) to ON(1) (rising
edge)
ON(1) if it was
OFF(0), or OFF(0)
if it was ON(1).
Input A changes from
ON(1) to OFF(0) (falling
edge)
unchanged
Input A
Toggle/Flip-Flop
Result
ONE SHOT
Rising edge of Input A turns Result
ON for one machine scan cycle.
Input A is ON(1) for any
length of time
ON(1) for 1 scan
cycle of the
instrument, then
OFF(0)
Result
Input A
One Shot
PASS
Passes Input A’s state unchanged to
CONDITION TYPE.
Input A changes state
same as Input A
Summary of Contents for VRX180
Page 1: ...Issue 3 03 03 US1I 6228 Video Recorder VRX180 User Manual ...
Page 2: ...Issue 3 03 03 US1I 6228 ...
Page 6: ...iv Video Recorder User Manual ...
Page 48: ...Installation Video Recorder User Manual 34 ...
Page 222: ...Setpoint Profiler Video Recorder User Manual 208 ...
Page 234: ...Online Operations Using Primary Displays Video Recorder User Manual 220 ...
Page 278: ...Appendix A Video Recorder User Manual 264 ...