8
These EuroNorms and harmonized standards were applied:
•
EN61000-6-3: 2001 Emission standard for residential environments (EN55022 Class
B);
•
EN50130-4: 1996 + A1: 1998 Alarm/security immunity requirements;
•
EN60950-1: 2006, Safety of ITE;
•
EN61000-3-2: 2006, Power-line Harmonics;
•
EN61000-3-3: 1995, Flicker;
•
TBR-21 (CTR-21) for PSTN and PBX.
Specification Summary
Caution
This equipment shall be connected to an earthed mains outlet.
Specification
Description
Operating
Environment
Temperature
40°F to 104°F (+5°C to +40°C), EN 50130-4 Environmental Class 1
Power
100 - 240 V~, 50 / 60 Hz, auto-ranging
Heat dissipation
620 BTU/hr
Interface
Cable requirement
Cables included with the unit are listed in
, on
Other connectors: BNC (video IN/OUT, public display), PC mouse,
PC keyboard, RJ-11 (dial-up), RJ-45 (LAN), USB, audio card
(OUT/MIC IN), screw terminal connectors (ALARM & CONTROL),
and custom RJ-45 (serial ports).
Network access
Auto-sensing for 100BaseT or 10BaseT. LAN/WAN use through
DSL or cable.
Modem
Internal. Programmable. Complies with FCC (ACTA) Part 68,
Industry Canada, TBR-21 - Public Switched Telephone Network
(PSTN) and Private Branch Exchange (PBX).
Local video output
Television monitor, for public display.
VGA monitor, for operation and/or public display.
DVD-RW drive
For unit upgrade and/or duplicating and distributing video clips.
Approvals
UL 60950-1
ETL listed for US and Canada (cETLus)
EN 60950-1
CE report, CB scheme report and certificate
EN 50130-4
Security system immunity requirements (UPS required)
EN 61000-6-3
RF emissions, residential environments (EN 55022 Class B)