example, B2000454657374 will compare the string at the current
cursor position with the 4 character string “Test.”
Refer to the
ASCII Conversion Chart,
beginning on page A-3
for decimal, hex and character codes.
Check for a number
EC
Check to make sure there is an ASCII number at the
current cursor position. The format is aborted if the character is not
numeric.
EC Example: Only output the data if the bar code begins with a
number
If you will only accept data from bar codes that begin with a
number, you can use EC to check for the number.
Command string:
ECF10D
EC is the “Check for a number”
command F1 is the “Send all characters”
command 0D is the hex value for a CR
If this bar code is read,
the format fails.
If this bar code is read:
the data is output as:
1234AB
<CR>
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the
current cursor position. The format is aborted if the character is
numeric.
ED Example: Only output the data if the bar code begins with a
letter
If you will only accept data from bar codes that begin with a letter,
you can use ED to check for the number.
Command string:
EDF10D
ED is the “Check for a non-numeric character” command
F1 is the “Send all characters” command
0D is the hex value for a CR
If this bar code is read,
the format fails.
5-14
Summary of Contents for N431X
Page 1: ...N431X Decoded Laser Scan Engine User s Guide ...
Page 6: ......
Page 14: ...x ...
Page 20: ...1 6 ...
Page 74: ...4 10 ...
Page 160: ...6 68 ...
Page 164: ...7 4 ...
Page 168: ...8 4 ...
Page 202: ...9 34 ...
Page 216: ...A 10 ...
Page 217: ......
Page 219: ...Sample Symbols Matrix 2 of 5 6543210 GS1 DataBar 01 00123456789012 ...
Page 220: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Page 222: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 N431X UG Rev B 12 12 ...