HW5600C Portable Electrical Generator Owner’s Manual
www.honeywellgenerators.com
21
Air Filter Maintenance
5.
Reinstall the fuel cap (A) and tighten.
NOTE:
Occasional, light spark knock, "pinging", or rattling noise
is normal while operating under heavy loads. If spark
knock, pinging, or rattling occurs at a steady engine
speed, under normal load, drain fuel (page 26) and refill
with fresh gasoline. If noise persists, see an authorized
generator dealer.
Air Filter Maintenance
Clean air filter every 50 hours of generator operation. If
operating generator in extremely dusty areas, clean air fil-
ter more frequently.
1.
Stop engine if it is running. Allow to completely cool.
2.
Remove air cleaner cover.
2A.
Turn thumbscrew counterclock wise to loosen and
remove.
2B.
Pull bottom of air cleaner cover out and lift up to
release plastic tabs.
3.
Remove air filter.
4.
Wash air filter in a solution of household soap and
warm water.
5.
Rinse parts thoroughly with water.
NOTICE
Running engine with persistent spark knock or pinging can
cause engine damage. Warranty does not cover parts dam-
aged by misuse.
NOTICE
A dirty air filter will restrict air flow to carburetor, which may
cause poor engine performance or damage.
NEVER run the generator without air cleaner assembly prop-
erly attached.
Gasoline and flammable solvents can cause fire or
explosion. NEVER use gasoline or flammable sol-
vent to clean air filter element.
• Use only household soap and water to clean air filter
element.
To clean air filter, you will need:
Household soap and water
Clean, dry cloth
Clean engine oil
WARNING
FIGURE 32:
Air Cleaner Cover
FIGURE 33:
Air Cleaner Cover
FIGURE 34:
Air Filter Removal
FIGURE 35:
Wash Air Filter
Summary of Contents for HW5600C
Page 87: ... ...