- 2 -

Inserting/changing batteries

The radiator controller is set for the following battery 
type:
•  2 Alkaline mignon cells 1.5 V, type LR6, AA, AM3
You can alternatively use the following batteries/
accumulators:
•  Lithium 1.5 V, type LR6, AA, AM3
•  NiMH 1.5 V, type LR6, AA, AM3

i

If lithium or NiMH batteries are used, Parameter 14 
has to be set correctly, see Section 9.

3.

2.

1.

+

+

1. Move the front part slightly upwards and remove it 

downwards.

The battery compartment is now accessible.

2. Insert the batteries.   

Ensure that the polarity is correct.

3. Put the front part back on and push downward.

The software version number, then the language 

deutsch

 (German) is displayed.

4. If applicable, use the adjustment dial to select a 

different language.

5. Confirm the selected language with the 

 OK 

 button.

hour

 is displayed.

i

The language selection is only displayed during initial 
commissioning. During future battery changes setting 
of time and date is prompted directly.

i

The battery life of new mignon cells amounts to 
approx. 2 years. The batteries need changing when 
the symbol 

 flashes. All the settings are retained 

when the batteries are changed.

WaRnIng

Explosion hazard!

 

f

Non-rechargeable batteries.

 

f

Never short-circuit batteries or throw them 
into fire.

 

f

Dispose of used batteries ecologically.

Setting the time and date

1. When 

hour

 is displayed, use the adjustment dial to 

set the current hour and confirm with 

 OK 

.

minute

 is displayed.

2. Use the adjustment dial to set the current minute and 

confirm with 

 OK 

.

year

 is displayed.

3. Use the adjustment dial to set the current year and 

confirm with 

 OK 

.

month

 is displayed.

4. Use the adjustment dial to set the current month and 

confirm with 

 OK 

.

day

 is displayed.

5. Use the adjustment dial to set the current day and 

confirm with 

 OK 

The normal display with set temperature and selected 
operating mode is displayed.

Mounting the radiator controller

The radiator controller can be mounted easily on all 
common radiator valves with a connection M30 x 1.5 
without causing dirt or water staining.

WaRnIng

Damage to the radiator controller due 
to short-circuiting through humidity and 
moisture!

 

f

Mount the radiator controller in dry, closed 
rooms only.

 

f

Protect the radiator controller against 
humidity, moisture, dust, direct sunlight or 
high heat irradiation.

Removing the old thermostat head

1.

2.

1. Turn the old thermostat head to the left until it stops 

and loosen the mounting.

2. Remove the old thermostat head from the radiator 

valve.

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...