opening the valve

 

f

Use the 

AUTO/ECO/MANU

 button to change to 

automatic mode.

– or –

 

f

Set the desired temperature in manual operation.

Child-proofing / operation lock

You can block the radiator controller to protect it against 
unauthorised operation:

 

f

Keep the 

AUTO/ECO/MANU

 and 

PROG

 buttons 

pressed simultaneously for at least 3 seconds. 

The symbol   is displayed.

i

The same key combination is used to release the 
radiator controller again for operation.

11. Help with problems

Error table

Problem/
Display

Cause

Remedy

 flashes

Batteries flat

Replace the batteries.

e1 
sensor

Device defective

Replace the device.

e2 
valve

Motor cannot be 
moved.

Check the 
installation. If 
appropriate, remove 
the dirt.

The radiator 
does not 
become cold.

The radiator valve 
does not close 
fully.

Check the 
installation. If 
appropriate, change 
to full-stroke mode 
(Parameter 8).

The room 
does not heat 
up during 
optimisation

Heating is not 
switched on in 
time

Ensure that the 
heating system is 
switched on.

Motor does not 
move

Valve baseplate 
not interlocked

Set the slide to the 
position

 

.

Emergency operation when batteries are flat

1. Unlock the radiator controller. To do so, slide the slide 

at the radiator controller towards the 

.

2. Pull the radiator controller off the valve baseplate.
3. Operate the radiator valve by hand using the 

adjustment dial on the valve baseplate.

+

Restoring the factory setting

1. Keep the 

PROG

 button pressed for approximately 

10 seconds until Parameter 1 flashes (left-hand digit). 

2. Use the adjustment dial to select Parameter 16 (left-

hand digit) and Setting 1 (right-hand digit). 

3. Press the 

 OK 

 button to restore the factory setting.

12. technical data

Type

HR30

Protection class

IP30

Supply voltage

Batteries 2 x 1.5 V; 
type LR6, AA, AM3

Connection to the radiator

M30 x 1.5 

Ambient temperature

0 ... 50 °C

Dimensions

94 x 50 x 69 mm

Ambient conditions

For living area, business and 
trade sections as well as 
small businesses

Humidity

10 ... 90% rel. humidity

13. Disposal

The radiator controller has to be disposed of in 
accordance with WEEE directive 2002/96/EC – 
Waste Electrical and Electronic Equipment directive.

 

f

Dispose of the packaging and product 
in a corresponding recycling centre.

 

f

Do not dispose of the unit with the 
domestic refuse.

 

f

Do not burn the product.

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...

Reviews: