background image

- 5 -

Week program 1: at home all day

Factory preset time program is set for each day of the 
week (Mo – Su):

Heating

20 °C

16 °C

Lowering/

saving

Switching 
point 1

Switching 
point 2

Switc

hing 

point time

temperature

1

6:00 – 22:00

 

20 °C (Comfort temperature 1)

2

22:00 – 6:00

 

16 °C (Conserve temperature)

i

•  Two further week programs are stored in the 

radiator controller. Further information is available 
in Section 9. 

•  You can also adapt one of the stored week 

programs to your individual requirements, see 
Section 8. 

Modifying the temperature temporarily

If you want to change the temperature specified by the 
time program 

temporarily

:

 

f

Set your desired temperature using the adjustment 
dial.

The change remains in effect until the next switching 
point.

i

The process of changing the temperatures 
permanently is described in Section 7.

Saving energy in ECo mode

In ECO mode the room temperature in automatic mode 
specified by the time program is decreased by 3 °C.

 

f

To activate ECO mode press the button 

AUTO/ECO/

MANU

 until 

economy

 is displayed.

The displayed temperature is reduced by 3 °C

.

ECO mode runs until you press the button 

AUTO/

ECO/MANU

 again and select a different operating 

mode.

Manual mode

In manual mode the radiator controller operates at 
the (manually) set temperature until you change the 
temperature or change to a different operating mode. 

 

f

To activate the manual mode press the button 

AUTO/ECO/MANU

 until 

manual

 is displayed.

The temperature can be adjusted manually using the 
adjustment dial

.

Manual mode runs until you press the button 

AUTO/

ECO/MANU

 again and select a different operating 

mode.

6. Programming – operating modes

overview of the operating modes

•  "Party" operating mode: In this operating mode you 

can specify a temperature for a number of hours. 
After the set period has expired, the radiator controller 
changes to automatic mode.

•  "Day off" operating mode:

 

If a public holiday lies 

during the week, the automatic mode settings may 
not meet your requirements on these days. In such 
cases you can activate a “Day off” program for one 
or more days. After the set period has expired, the 
radiator controller changes to automatic mode. 

•  "Holiday" operating mode: In this operating mode 

you can specify a temperature for a specific number 
of days. After the set period has expired, the radiator 
controller changes to automatic mode.

Selecting operating modes

Selecting the "Party" or "Holiday" operating 
mode

1. Press the 

PROG

 button and turn the adjustment dial 

to the left until 

party

 or 

holiday

 is displayed.

2. Confirm the selected operating mode with the 

 OK 

 

button.

Hours or Days flashes.

3. Use the adjustment dial to set the desired number of 

hours or days and confirm with 

 OK 

.

The temperature display flashes.

4. Use the adjustment dial to set the desired temperature 

and confirm with 

 OK 

.

The selected operating mode and the set temperature 
are displayed.

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...

Reviews: