- 9 -

Switc

hing 

point time

temperature

1

6:00 – 9:00

 

20 °C (Comfort temperature 1)

2

9:00 – 12:00

 

16 °C (Conserve temperature)

3

12:00 – 13:00

 

20 °C (Comfort temperature 1)

4

13:00 –17:00

 

16 °C (Conserve temperature)

5

17:00 – 22:00

 

22 °C (Comfort temperature 2)

6

22:00 – 6:00

 

16 °C (Conserve temperature)

• 

Week program 3 

(4 switching points):

  

Mo – Fr working half-time 
Sa – Su like Week program 1

2

3

Conserve

Heating

Heating

20 °C

16 °C

22 °C

4

Switching points

Switc

hing 

point time

temperature

1. 

6:00 to 9:00

 

20 °C (Comfort temperature 1)

2.

9:00 to 13:00

 

16 °C (Conserve temperature)

3.

13:00 to 
22:00

 

22 °C (Comfort temperature 2)

4.

22:00 to 6:00

 

16 °C (Conserve temperature)

Parameter 3 – Backlight

The display has a backlight in order to facilitate reading 
of information. 
•  The backlight is activated when the adjustment dial 

moves or a button is pressed. 

•  The backlight switches off if no action is carried out at 

the radiator controller for approx. 7 seconds in order 
to save energy.

Parameters 5 to 7 – Window function

In order to save energy the radiator controller closes the 
radiator valve when you open a window resulting in a 
sudden drop of the temperature. 

When you close the window so that the temperature 
rises the radiator controller opens the radiator valve 
again.
If you should ever forget to close the window, the 
radiator controller opens automatically after the set time 
in order to ensure frost protection.

Parameter 8 – Valve stroke

The radiator controller operates with the optimum valve 
stroke set in the factory.
If the entire valve stroke is to be used or if the valve does 
not close completely, activate the full-stroke mode.

Parameter 9 – temperature representation in the 
display

•  In the factory setting the set or programmed 

temperature (Comfort temperature 1, 2 or the 
Conserve temperature) is displayed.

•  With the setting "measured temperature" the 

measured room temperature is displayed. A 
changeover to the set temperature is carried out 
by turning the adjustment dial or pressing a button. 
If required, the temperature can now be reset. The 
display returns to the measured temperature after 
approx. 3 seconds.

Parameter 12 – optimisation function

Without optimisation

 (factory setting) the radiator 

controller begins to raise or lower the room temperature 
at the programmed time. In order to have the bathroom 
warm at 7:00, the switching point must be preponed, 
otherwise heating would start only at 7:00. Possibly the 
switching point is preponed too much, so that heating 
starts much earlier than actually needed.

With optimisation

 the room has already reached the 

desired temperature at the programmed beginning since 
the radiator controller has begun to raise or lower the 
room temperature at an optimal time.
•  Optimum start 

The room is heated up at an optimum moment to 
reach the programmed temperature.

•  Optimum start/stop: 

The room is heated up at an optimum moment and 
cooled down earlier.

Switching point

Without

Optimisation

Optimum

 Start

Optimum

 Stop

Without

Optimisation

Switching point

°C

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...

Reviews: