- 10 -

Parameter 13 – temperature offset

Since the radiator controller measures the room 
temperature in the area of the radiator, it is possible 
that this temperature deviates from the temperature 
measured at a different point in the room.
If, for example, 20 °C is measured in the room and at the 
radiator 21.5 °C, this effect can be compensated by an 
offset of –1.5 °C. The display at the radiator controller 
remains unchanged.

Parameter 15 – Display of the valve position

When this parameter is activated (setting "1"), the 
calculated valve position is displayed (0 to 100% 
opened) briefly.
The main display is shown again after approx. 3 minutes 
or when the 

AUTO

 button is pressed. 

Changing parameters

1. Keep the 

PROG

 button pressed for at least 

10 seconds until Parameter 1 flashes (left-hand digit). 

The right-hand digit shows the current setting.
The parameter is displayed additionally in plain text.
For example, the display 

1 1

 stands for Parameter 1 

(language) with Setting 1 (German).
2. If desired, use the adjustment dial to select a different 

parameter (left-hand digit).

3. Press the 

 OK 

 button to edit the parameter.

The current setting of the parameter flashes (right 
hand digit).

4. Use the adjustment dial to set the desired setting 

(right-hand digit) and confirm with 

 OK 

.

5. The parameter being edited flashes (left-hand digit).

6. For the further parameters repeat Steps 2 to 4. 
7. Use the 

AUTO

 button to return to automatic mode.

10. Further functions

Monitoring functions

Window function

If you open a window causing the temperature to drop, 
the radiator controller closes the radiator valve in order 
to save energy.

window

 is displayed.

When the temperature rises again, but at the latest after 
the set period (factory setting: 30 minutes), the radiator 
controller opens the radiator valve again.
You can also open the radiator valve beforehand by 
pressing the 

AUTO

 button or turning the adjustment 

dial.
The sensitivity of the radiator controller to a temperature 
drop or temperature rise can be set, see Section 9, 
Parameters 5 to 7.

Valve protection

If the radiator valve has not been opened completely for 
2 weeks, a self test is carried out. The radiator controller 
opens the radiator valve briefly on the subsequent 
Monday in order to prevent seizing. 

cycl

 is displayed.

Frost protection

If the temperature drops below 5 °C, the radiator 
controller opens the radiator valve until the temperature 
rises above 6 °C again. This prevents the heating from 
freezing up. 

frost

 is displayed. 

i

The heating may not be switched off. Otherwise the 
radiator controller cannot carry out the frost protec-
tion function.

Summer break

If you have switched off the central heating system 
in summer and do not want to waste the batteries of 
the radiator controller, you can close the radiator valve 
continuously.

Closing the valve

1. Press the button 

AUTO/ECO/MANU

 until 

manual

 

is displayed.

2. Turn the adjustment dial anti-clockwise until 

off

 is 

displayed. 

The radiator valve now remains closed. The valve and 
frost protection function remains active.

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...

Reviews: